dBm, Watts & Volts RF Power Converter
Convert measured RF power or sine-wave voltage, then translate between transmitter output, ERP and EIRP.
Results
Preset estimate- Conducted power
- 1 W
- Load voltage
- 7.071068 Vrms
- Load voltage
- 20 Vpp
Transmitter output
- Milliwatts
- 1,000 mW
- Microwatts
- 1,000,000 µW
- Load resistance
- 50 Ω
Radiated power & antenna reference
- EIRP
- 32.15 dBm
- Equivalent isotropic watts
- 1.64059 W
- ERP
- 30 dBm
- Equivalent dipole watts
- 1 W
- Gain relative to isotropic
- 2.15 dBi
- Gain relative to dipole
- 0 dBd
| dBm | Watts | Vrms · 50 Ω | Vpp · 50 Ω | Vrms · 75 Ω | Vpp · 75 Ω |
|---|---|---|---|---|---|
| -30 | 0.000001 | 0.007071 | 0.02 | 0.00866 | 0.024495 |
| 0 | 0.001 | 0.223607 | 0.632456 | 0.273861 | 0.774597 |
| 10 | 0.01 | 0.707107 | 2 | 0.866025 | 2.44949 |
| 20 | 0.1 | 2.236068 | 6.324555 | 2.738613 | 7.745967 |
| 30 | 1 | 7.071068 | 20 | 8.660254 | 24.494897 |
| 40 | 10 | 22.36068 | 63.245553 | 27.386128 | 77.459667 |
Worked example
Convert measured RF power or sine-wave voltage, then translate between transmitter output, ERP and EIRP.
- Conducted power
- 30 dBm
- Conducted power
- 1 W
- Load voltage
- 7.071068 Vrms
- Load voltage
- 20 Vpp
Formulas & assumptions
- P(W) = 10^((dBm − 30) / 10). dBm = 10 log₁₀(P(W)) + 30.
- Vrms = √(P × R) across a matched resistive load. Vpp = 2√2 × Vrms for a sine wave.
- Gain (dBi) = gain (dBd) + 2.15. EIRP = conducted dBm − feed loss + gain in dBi. ERP = EIRP − 2.15 dB.
Voltage conversions are for a sine wave across the stated matched load. A scope in high-impedance mode can show a different source voltage. Modulated RF often needs separate peak and average measurements.
When the input is ERP or EIRP, the tool works back to conducted power before converting to port voltage.
Questions & answers
How many watts are 30 dBm?
30 dBm is 1 W. It corresponds to about 7.07 Vrms or 20 Vpp across a matched 50 Ω load for a sinusoid.
Does a 75-ohm load change the dBm-to-watts calculation?
Watts and dBm both describe power, independent of resistance. Load resistance changes the voltage corresponding to the same power.
How do I convert a gain of 3 dBd to dBi?