75 Ω DAB tuner input

A VHF tuner’s extracted line impedance is 48 + j21 Ω around band III.

Readout

Conjugate match / ABCD
VSWR BEFORE
1.7553:1
VSWR AFTER
1.0048:1
LOW-PASS IL
0.020854dB
HIGH-PASS IL
0.049955dB
Matched at f₀At least one finite-Q topology meets 2:1 VSWR.
L-network match live schematicNormalized Smith chart|Γ|● LoadLow / high pass● MatchConjugate match circuitsSOURCE → LOADLOW-PASS10.61 nH7.074 pFHIGH-PASS12.41 pF70.74 nHMATCHEDVSWR 2:1MISMATCH

Conjugate L-sections

QuantityLow-passHigh-pass
Series component10.61 nH12.41 pF
Shunt component7.0736 pF70.736 nH
Shunt locationSource sideSource side
Loaded Q0.750.75
3 dB fractional BWBeyond sweep507.65 % (0.1172–1.2594 GHz)
≤ 2:1 VSWR BWBeyond sweep119.07 % (0.16012–0.42804 GHz)
Finite-Q |Γ| / VSWR0.0023981 / 1.0048:10.0057355 / 1.0115:1
Ideal |Γ| at f₀04.737e-17
Transducer loss0.020854 dB0.049955 dB

Unmatched load

QuantityValue
Load reflection |Γ|0.27412
Load VSWR1.7553:1

How to read this result

The solver tries both shunt placements. Each placement requires a real positive square root for the intermediate susceptance or reactance. Reported finite-Q transducer loss includes remaining mismatch. The Smith paths show the ideal conjugate match.

Bandwidth treats the measured load reactance as a single ideal L or C and keeps the load resistance and inductor Q fixed. Component self-resonance, capacitor ESR and layout parasitics can change the match.

Methods & references

L-network match examples

All 50 examples