2.45 GHz antenna match

A VNA measures a 110 − j22 Ω antenna feed on a 50 Ω system.

Readout

Conjugate match / ABCD
VSWR BEFORE
2.3096:1
VSWR AFTER
1.0206:1
LOW-PASS IL
0.089156dB
HIGH-PASS IL
0.10474dB
Matched at f₀At least one finite-Q topology meets 2:1 VSWR.
L-network match live schematicNormalized Smith chart|Γ|● LoadLow / high pass● MatchConjugate match circuitsSOURCE → LOADLOW-PASS3.686 nH0.5309 pFHIGH-PASS1.145 pF5.567 nHMATCHEDVSWR 2:1MISMATCH

Conjugate L-sections

QuantityLow-passHigh-pass
Series component3.6862 nH1.1448 pF
Shunt component0.53088 pF5.5671 nH
Shunt locationLoad sideLoad side
Loaded Q1.13491.1349
3 dB fractional BW180.13 % (0.36907–4.7823 GHz)Beyond sweep
≤ 2:1 VSWR BW93.857 % (1.1856–3.485 GHz)215.87 % (1.8158–7.1045 GHz)
Finite-Q |Γ| / VSWR0.010212 / 1.0206:10.011988 / 1.0243:1
Ideal |Γ| at f₀3.8104e-171.4803e-16
Transducer loss0.089156 dB0.10474 dB

Unmatched load

QuantityValue
Load reflection |Γ|0.39569
Load VSWR2.3096:1

How to read this result

The solver tries both shunt placements. Each placement requires a real positive square root for the intermediate susceptance or reactance. Reported finite-Q transducer loss includes remaining mismatch. The Smith paths show the ideal conjugate match.

Bandwidth treats the measured load reactance as a single ideal L or C and keeps the load resistance and inductor Q fixed. Component self-resonance, capacitor ESR and layout parasitics can change the match.

Methods & references

L-network match examples

All 50 examples