Complex load with a feed-line trim

A 5.8 GHz radiator has a 82 − j31 Ω feed impedance before transformation.

Readout

Transmission-line transforms
CENTER VSWR
1:1
BAND MAX VSWR
1.4155:1
GUIDED λ
30.564mm
SECTION λ/4
7.641mm
Within 2:1 VSWRA synthesized solution passes across the sampled design band.
Quarter-wave & stub live schematicStepped microstrip layoutλ / 445.64 Ω35.54 Ω27.68 ΩFeedLoadλ/4 7.641 mmTrim 6.3304 mmVSWR across design bandLOSSLESS11.62.20.8111.19TransformerFrequency / f₀1:1 MATCHVSWR 2:1MISMATCH

Band & match results

QuantityValue
Unmatched |Γ| / VSWR0.32859 / 1.9788:1
Frequency range4.698–6.902 GHz
Guided wavelength30.564 mm / 1203.3 mil

Line sections, source to load

SectionImpedanceLength
145.641 Ω7.641 mm / 300.83 mil
235.544 Ω7.641 mm / 300.83 mil
327.682 Ω7.641 mm / 300.83 mil
Feed-line trim50 Ω6.3304 mm / 249.23 mil
Load after trim25.268 Ω—

How to read this result

Quarter-wave section impedances are synthesized from log impedance steps. Stub mode rotates the complex load to each unity-conductance crossing and cancels its normalized susceptance. The band summary reports the worst of 257 samples.

A complex load uses an added feed-line section to reach a real impedance. Binomial/Chebyshev synthesis uses small-reflection theory and the displayed VSWR comes from exact lossless cascading. Stub open-end fringing, short-via inductance and dispersion are outside the model.