Shorted shunt stub for X-band

A shorted 60 Ω shunt stub tunes a capacitive 10 GHz fixture.

Readout

Transmission-line transforms
CENTER VSWR
1:1
BAND MAX VSWR
1.1564:1
GUIDED λ
18.557mm
STUB 1 LENGTH
2.4878mm
Within 2:1 VSWRA synthesized solution passes across the sampled design band.
Quarter-wave & stub live schematicShunt-stub layoutSHORTSolution 1d 1.7154 mml 2.4878 mmSolution 2d 5.3035 mml 6.7905 mmVSWR across design bandLOSSLESS11.62.20.9111.09Solution 1Solution 2Frequency / f₀1:1 MATCHVSWR 2:1MISMATCH

Band & match results

QuantityValue
Unmatched |Γ| / VSWR0.34842 / 2.0695:1
Frequency range9.1–10.9 GHz
Guided wavelength18.557 mm / 730.58 mil

Both shunt-stub solutions

QuantitySolution 1Solution 2
Distance from load / λg0.0924390.2858
Stub electrical length / λg0.134070.36593
Distance1.7154 mm / 67.534 mil5.3035 mm / 208.8 mil
Stub length2.4878 mm / 97.945 mil6.7905 mm / 267.34 mil
Susceptance to cancel0.74342-0.74342
Center VSWR1:11:1
Sampled band max1.1564:11.8124:1

How to read this result

Quarter-wave section impedances are synthesized from log impedance steps. Stub mode rotates the complex load to each unity-conductance crossing and cancels its normalized susceptance. The band summary reports the worst of 257 samples.

A complex load uses an added feed-line section to reach a real impedance. Binomial/Chebyshev synthesis uses small-reflection theory and the displayed VSWR comes from exact lossless cascading. Stub open-end fringing, short-via inductance and dispersion are outside the model.

Methods & references

Quarter-wave & stub examples

All 50 examples