A 2.45 GHz feed transforms a resistive antenna terminal with one printed section.
Open shunt stub for 2.1 GHz
A loaded microstrip feed needs a printed open stub on a dense adapter.
Readout
Transmission-line transformsBand & match results
| Quantity | Value |
|---|---|
| Unmatched |Γ| / VSWR | 0.47039 / 2.7764:1 |
| Frequency range | 1.785–2.415 GHz |
| Guided wavelength | 83.258 mm / 3277.9 mil |
Both shunt-stub solutions
| Quantity | Solution 1 | Solution 2 |
|---|---|---|
| Distance from load / λg | 0.27975 | 0.4518 |
| Stub electrical length / λg | 0.36991 | 0.13009 |
| Distance | 23.291 mm / 916.98 mil | 37.616 mm / 1481 mil |
| Stub length | 30.798 mm / 1212.5 mil | 10.831 mm / 426.42 mil |
| Susceptance to cancel | 1.0661 | -1.0661 |
| Center VSWR | 1:1 | 1:1 |
| Sampled band max | 6.6326:1 | 4.1833:1 |
How to read this result
Quarter-wave section impedances are synthesized from log impedance steps. Stub mode rotates the complex load to each unity-conductance crossing and cancels its normalized susceptance. The band summary reports the worst of 257 samples.
A complex load uses an added feed-line section to reach a real impedance. Binomial/Chebyshev synthesis uses small-reflection theory and the displayed VSWR comes from exact lossless cascading. Stub open-end fringing, short-via inductance and dispersion are outside the model.
Quarter-wave & stub examples
All 50 examplesAn array feed needs flatter center-band match than a single quarter-wave section.
A moderately wide band is specified for a 50 Ω-to-92 Ω feed transition.
A 5.8 GHz radiator has a 82 − j31 Ω feed impedance before transformation.
A loaded microstrip feed needs a printed open stub on a dense adapter.
A shorted 60 Ω shunt stub tunes a capacitive 10 GHz fixture.