A 2.45 GHz feed transforms a resistive antenna terminal with one printed section.
Shorted shunt stub for X-band
A shorted 60 Ω shunt stub tunes a capacitive 10 GHz fixture.
Readout
Transmission-line transformsBand & match results
| Quantity | Value |
|---|---|
| Unmatched |Γ| / VSWR | 0.34842 / 2.0695:1 |
| Frequency range | 9.1–10.9 GHz |
| Guided wavelength | 18.557 mm / 730.58 mil |
Both shunt-stub solutions
| Quantity | Solution 1 | Solution 2 |
|---|---|---|
| Distance from load / λg | 0.092439 | 0.2858 |
| Stub electrical length / λg | 0.13407 | 0.36593 |
| Distance | 1.7154 mm / 67.534 mil | 5.3035 mm / 208.8 mil |
| Stub length | 2.4878 mm / 97.945 mil | 6.7905 mm / 267.34 mil |
| Susceptance to cancel | 0.74342 | -0.74342 |
| Center VSWR | 1:1 | 1:1 |
| Sampled band max | 1.1564:1 | 1.8124:1 |
How to read this result
Quarter-wave section impedances are synthesized from log impedance steps. Stub mode rotates the complex load to each unity-conductance crossing and cancels its normalized susceptance. The band summary reports the worst of 257 samples.
A complex load uses an added feed-line section to reach a real impedance. Binomial/Chebyshev synthesis uses small-reflection theory and the displayed VSWR comes from exact lossless cascading. Stub open-end fringing, short-via inductance and dispersion are outside the model.
Quarter-wave & stub examples
All 50 examplesAn array feed needs flatter center-band match than a single quarter-wave section.
A moderately wide band is specified for a 50 Ω-to-92 Ω feed transition.
A 5.8 GHz radiator has a 82 − j31 Ω feed impedance before transformation.
A loaded microstrip feed needs a printed open stub on a dense adapter.
A shorted 60 Ω shunt stub tunes a capacitive 10 GHz fixture.