RobotKinematicsLab

Carton vacuum with porous stock

A carton palletizer uses a vacuum head with pressure reduced by leakage in the stock.

Results ↓

Parameters

Payload and load case
kg
m/s²
×
Grip capacity
mm
kPa

Live results

Warn

For horizontal transfer, available grip meets the requested factor with less than 10% reserve.

Required force
204.907 N
Available
217.712 N
Achieved SF
2.12499 ×
Force margin
12.806 N
Grip free-body diagram
Grip free-body diagram6 SEALED CUPSHORIZONTAL TRANSFERAvailable vs requiredMINIMUM
  • Contact force
  • Payload force
  • Workpiece
Grip load case
QuantityValue
Gravity + acceleration envelope102.454 N
Factored payload load204.907 N
Required total holding force204.907 N
Derated holding force217.712 N
Theoretical normal holding force494.801 N
Effective area per cup0.0019635 m²
Signed reserve12.806 N
Required safety factor2 ×

Formula trace

  1. Envelope payload

    Fload = m(g + aₘₐₓ); Ftarget = SF · Fload

    Fload = 102.454 NFtarget = 204.907 N

    kg × m/s² = N. For horizontal and stop cases the sum bounds simultaneous weight and inertial load.

  2. Cup holding force

    A = π(d/2)²; Fideal = n Δp A; Fusable = Fideal · k

    A = 0.0019635 m²Fusable = 217.712 N

    Pa × m² = N. Enter the measured vacuum differential at the cup and a shear/orientation factor.

  3. Compare reserve

    margin = Favailable − Frequired; SFactual = Fusable / Fload

    margin = 12.806 NSFactual = 2.12499 ×

    Pass uses 10% spare capacity on top of the requested factor. Equality meets demand with zero spare.