RobotKinematicsLab

Clean assembly tray label placement

A small rotary head aligns a label with a tray edge in a clean assembly station.

Results ↓

Parameters

Geometry
m
m
m
Forward pose
°
°
°
Inverse target
m
m
°
Joint limits
°
°
°
°
°
°

Live results

Pass

Both inverse branches are reachable and within the joint limits.

Tool X
0.497084 m
Tool Y
0.0826772 m
Tool angle
20 °
IK branches
2 / 2
Workspace and elbow branches
Workspace and elbow branchesXY WORK PLANECLOSED REACH RINGWorkspace ringREACH WINDOW
  • Entered pose
  • Elbow-up
  • Elbow-down
Reach and limits
QuantityValue
Wrist radius0.306852 m
Inner radius0.09 m
Outer radius0.53 m
Signed ring clearance0.216852 m
Wrist X0.252058 m
Wrist Y-0.175 m
Joint solutions
Poseθ1θ2θ3Limit check
Forward input-24 °78 °-34 °J1 OK · J2 OK · J3 OK
Elbow-up7.01357 °-111.659 °74.6451 °J1 OK · J2 OK · J3 OK
Elbow-down-76.5569 °111.659 °-65.1017 °J1 OK · J2 OK · J3 OK

Formula trace

  1. Forward pose

    x = Σ Lᵢ cos(Σ θⱼ), y = Σ Lᵢ sin(Σ θⱼ), φ = Σ θᵢ

    x = 0.497084 my = 0.0826772 mφ = 20 °

    Lengths yield a Cartesian position. Trigonometry uses radians internally.

  2. Closed reach ring

    w = target − L₃[cos φ, sin φ] (3R); |L₁ − L₂| ≤ ‖w‖ ≤ L₁ + L₂

    rmin = 0.09 mr = 0.306852 mrmax = 0.53 m

    Compare wrist radius and ring edges in one length unit before solving angles.

  3. Inverse branches

    θ₂ = ±2 atan2(√(rₘₐₓ²−r²), √(r²−rₘᵢₙ²)); θ₁ = atan2(wᵧ,wₓ) − atan2(L₂ sin θ₂,L₁+L₂ cos θ₂)

    θ₂ up = -111.659 °θ₂ down = 111.659 °

    Elbow-up uses a negative principal θ₂ with +Y up. θ₃ = φ − θ₁ − θ₂ when active.