RobotKinematicsLab · Engineering worksheet
FANUC extended infeed lock-out
Jacobian & Singularity Analyzer · SI units
Singularity lock-out. Inverse joint rates are suppressed because the normalized minimum singular value is too small.
Active inputs
- Active joints
- 2R · translation
- Link 1 length
- 0.45 m
- Link 2 length
- 0.36 m
- Joint 1 angle
- 20 °
- Joint 2 angle
- 0 °
- X velocity
- 0.14 m/s
- Y velocity
- 0.04 m/s
- Joint rate limit
- 4 rad/s
- Determinant
- 0 m²
- Manipulability
- 0 m²
- Condition κ
- ∞ ×
- Peak rate
- Locked
- Velocity ellipse
- Singular axes
- Requested XY velocity
| Task row | Joint 1 | Joint 2 |
|---|---|---|
| X | -0.277036 m | -0.123127 m |
| Y | 0.761151 m | 0.338289 m |
| Quantity | Value |
|---|---|
| σ1 | 0.886397 m |
| σ2 | 0 m |
| σmin / σmax | 0 |
| Joint 1 rate | Locked |
| Joint 2 rate | Locked |
| XY ellipse semimajor | 0.886397 m/s |
| XY ellipse semiminor | 0 m/s |
Record fixture, tooling and controller assumptions before commissioning.