Metal roof storm yield for a garden cistern

A 1,600 ft² connected metal roof collects a 1.2-inch storm. A garden needs 25 gal/day for an 18-day dry spell.

Worked calculation

The first flush diverts 12.8 gallons per event. The usable dry reserve is 450 gallons, which implies a nominal 500-gallon tank at 90% usable volume.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Catchment and rainfall
ft²
in
in
in
Diversion and storage
US gal/1,000 ft²
US gal/day
Number of days the stored water should cover.
%

Results

Live

Roof catchment, first flush and tankStored yield from one storm 1,124.24 US gal. Nominal reserve tank capacity 500 US gal. ROOF CATCHMENTStorm yield1,124.24 US galFirst flush 12.8 US galCISTERN500 US galNominal capacity
Roof catchment, first flush and tank Schematic
Storm yield before diversion
1,137.04 US gal
First-flush diverter per event
12.8 US gal
Typical month yield
3,726.13 US gal
Annual yield
44,713.56 US gal
Runoff coefficient
0.95
Usable dry-spell reserve
450 US gal
Annual demand
9,125 US gal
Potential overflow from an empty tank
624.24 US gal
Potential demand days from storm
44.97

Apply this example to your roof

The surface coefficients are editable planning defaults. Use local rainfall sequences and demand schedules to check a tank purchase. A system for indoor or potable use requires the applicable water quality, treatment and cross-connection provisions.

Read the calculator method and references

Frequently asked questions

How does this metal roof scale an 8-gallon first flush?

Multiply 8 gallons per 1,000 ft² by the 1.6 catchment factor. That gives 12.8 gallons per reset.

Why can an empty 500-gallon garden tank overflow in this storm?

The single-storm yield exceeds the nominal 500-gallon volume. The 450-gallon reserve describes the water available to draw after filling. Provide an overflow route.