Rainwater Harvesting Yield & Cistern Sizing Calculator
Estimate roof catchment yield after first flush and size a cistern around daily demand and a dry spell.
Results
LiveCorrect the highlighted inputs to update your results.
- Stored yield from one storm
- Nominal reserve tank capacity
- Storm yield before diversion
- First-flush diverter per event
- Typical month yield
- Annual yield
- Runoff coefficient
- Usable dry-spell reserve
- Annual demand
- Potential overflow from an empty tank
- Potential demand days from storm
Worksheet inputs US customary
- Connected horizontal roof area
- 1,800 ft²
- Roof runoff coefficient
- Metal · 0.95
- Single storm depth
- 1 in
- Typical month rainfall
- 3.5 in
- Annual rainfall
- 42 in
- First flush per event and catchment area
- 10 US gal/1,000 ft²
- First-flush resets per typical month
- 5
- First-flush resets per year
- 60
- Daily water demand
- 32 US gal/day
- Dry-spell reserve
- 21
- Usable portion of tank capacity
- 90%
Compare rainfall supply with dry-spell demand
- Start with the connected horizontal catchment. In US units, each inch of rainfall over one square foot is 144 ÷ 231 gallons before losses. Multiply by the assumed runoff coefficient.
- Subtract the area-scaled first flush once for a storm, or once per entered reset for the monthly and annual estimates. The aggregate calculations use a simplified average-loss approach.
- Multiply daily demand by reserve days and divide by the usable percentage to size nominal storage. The overflow estimate starts with a physically empty tank and uses its full nominal volume. Water already in the tank reduces the available space.
The surface coefficients are editable planning defaults. Use local rainfall sequences and demand schedules to check a tank purchase. A system for indoor or potable use requires the applicable water quality, treatment and cross-connection provisions.
References
Frequently asked questions
Why use a horizontal roof footprint for rainwater harvest?
Vertically falling rainfall depth applies to the horizontal projection. The steeper deck has a larger surface, while its projected catchment remains the same.
How should first flush be counted in a monthly yield estimate?
Enter how often the diverter empties and refills in a typical month. Adjust that count for your climate and diverter design.
What is the difference between usable reserve and nominal tank capacity?
Usable reserve is the water you can draw. Nominal capacity includes volume below the outlet or otherwise unavailable.