Rainwater Harvesting Yield & Cistern Sizing Calculator

Estimate roof catchment yield after first flush and size a cistern around daily demand and a dry spell.

Inputs

Units
Catchment and rainfall
ft²
in
in
in
Diversion and storage
US gal/1,000 ft²
US gal/day
Number of days the stored water should cover.
%

Results

Live

Roof catchment, first flush and tankStored yield from one storm 1,047.97 US gal. Nominal reserve tank capacity 746.67 US gal. ROOF CATCHMENTStorm yield1,047.97 US galFirst flush 18 US galCISTERN746.67 US galNominal capacity
Roof catchment, first flush and tank Schematic
Storm yield before diversion
1,065.97 US gal
First-flush diverter per event
18 US gal
Typical month yield
3,640.91 US gal
Annual yield
43,690.91 US gal
Runoff coefficient
0.95
Usable dry-spell reserve
672 US gal
Annual demand
11,680 US gal
Potential overflow from an empty tank
301.31 US gal
Potential demand days from storm
32.75

Compare rainfall supply with dry-spell demand

  1. Start with the connected horizontal catchment. In US units, each inch of rainfall over one square foot is 144 ÷ 231 gallons before losses. Multiply by the assumed runoff coefficient.
  2. Subtract the area-scaled first flush once for a storm, or once per entered reset for the monthly and annual estimates. The aggregate calculations use a simplified average-loss approach.
  3. Multiply daily demand by reserve days and divide by the usable percentage to size nominal storage. The overflow estimate starts with a physically empty tank and uses its full nominal volume. Water already in the tank reduces the available space.

The surface coefficients are editable planning defaults. Use local rainfall sequences and demand schedules to check a tank purchase. A system for indoor or potable use requires the applicable water quality, treatment and cross-connection provisions.

References

Frequently asked questions

Why use a horizontal roof footprint for rainwater harvest?

Vertically falling rainfall depth applies to the horizontal projection. The steeper deck has a larger surface, while its projected catchment remains the same.

How should first flush be counted in a monthly yield estimate?

Enter how often the diverter empties and refills in a typical month. Adjust that count for your climate and diverter design.

What is the difference between usable reserve and nominal tank capacity?

Usable reserve is the water you can draw. Nominal capacity includes volume below the outlet or otherwise unavailable.