RoomAcousticLab · Calculation record
Shift noise dose example
Mixed shift with dual protection
Two noise-intensive tasks and two quieter periods form an eight-hour shift. Enter the higher label NRR for the dual-protection estimate.
Inputs
Set any unused segment duration to zero.
- OSHA HC dose
- 68.5%
- OSHA HC TWA
- 87.3dBA
- NIOSH dose
- 263.2%
- NIOSH TWA
- 89.2dBA
Shift exposure timeline
Illustrative scaleAn exposure criterion is reached
LimitOSHA PEL dose or NIOSH dose using the 80 dBA threshold is at or above 100%. This screen uses unprotected exposure.
Below actionAction levelAt / over limit
Input snapshot
- Segment 1 level
- 96 dBA
- Segment 1 duration
- 1 h
- Segment 2 level
- 89 dBA
- Segment 2 duration
- 3 h
- Segment 3 level
- 81 dBA
- Segment 3 duration
- 2 h
- Segment 4 level
- 74 dBA
- Segment 4 duration
- 2 h
- Protection
- Dual protection
- Label NRR (higher if dual)
- 30 dB
Calculation breakdown
- Total measured duration
- 8 h
- OSHA PEL dose · 90 dBA threshold
- 28.7%
- OSHA PEL TWA
- 81 dBA
- Continuous 3 dB dose · no threshold
- 265.1%
- Continuous 3 dB TWA
- 89.2 dBA
- Estimated protector attenuation
- 16.5 dB
- Estimated protected OSHA HC TWA
- 70.8 dBA
| Segment | Exposure | Length |
|---|---|---|
| 1 | 96 dBA | 1 h |
| 2 | 89 dBA | 3 h |
| 3 | 81 dBA | 2 h |
| 4 | 74 dBA | 2 h |
The A-weighted NRR estimate applies a 50% field factor to the adjusted label. Use the higher labelled NRR for dual protection. The exposure screen uses unprotected data. Personal dosimetry, fit testing and separate assessment of impulsive or peak noise are needed for workplace decisions.