RoomAcousticLab · Calculation record
Shift noise dose example
Full shift at 90 dBA
Eight hours at 90 dBA is the OSHA 100% PEL reference. Compare the same shift with the 85 dBA NIOSH criterion.
Inputs
Set any unused segment duration to zero.
- OSHA HC dose
- 100%
- OSHA HC TWA
- 90dBA
- NIOSH dose
- 317.5%
- NIOSH TWA
- 90dBA
Shift exposure timeline
Illustrative scaleAn exposure criterion is reached
LimitOSHA PEL dose or NIOSH dose using the 80 dBA threshold is at or above 100%. This screen uses unprotected exposure.
Below actionAction levelAt / over limit
Input snapshot
- Segment 1 level
- 90 dBA
- Segment 1 duration
- 8 h
- Segment 2 level
- 94 dBA
- Segment 2 duration
- 0 h
- Segment 3 level
- 82 dBA
- Segment 3 duration
- 0 h
- Segment 4 level
- 75 dBA
- Segment 4 duration
- 0 h
- Protection
- None
Calculation breakdown
- Total measured duration
- 8 h
- OSHA PEL dose · 90 dBA threshold
- 100%
- OSHA PEL TWA
- 90 dBA
- Continuous 3 dB dose · no threshold
- 317.5%
- Continuous 3 dB TWA
- 90 dBA
- Estimated protector attenuation
- 0 dB
- Estimated protected OSHA HC TWA
- 90 dBA
| Segment | Exposure | Length |
|---|---|---|
| 1 | 90 dBA | 8 h |
| 2 | Inactive | 0 h |
| 3 | Inactive | 0 h |
| 4 | Inactive | 0 h |
The A-weighted NRR estimate applies a 50% field factor to the adjusted label. Use the higher labelled NRR for dual protection. The exposure screen uses unprotected data. Personal dosimetry, fit testing and separate assessment of impulsive or peak noise are needed for workplace decisions.