Helmholtz resonator example

Shallow slatted ceiling cavity

A ceiling depth allowance restricts the cavity. Check the predicted tuning error when a low-frequency target has to fit the shallower backing.

Inputs

Panel & cavity
Frequency & air
Resonance
236.9Hz
Quarter wave
1,016.3Hz
Target error
111.9Hz
Open area
6%

Acoustic absorber cavity section

Illustrative scale
Cross-section of acoustic resonatorA panel opening feeds a rigidly backed air cavity. Geometry labels show the hole or slot dimension and cavity depth.SLATTED FACERIGID BACKINGSlot 6 mmDepth 85 mm
OpeningCavityRigid backing

Resonance outside the tuning window

Limit

The predicted peak is more than 15% from the target frequency.

Within 5%5–15% / reviewOver 15%

Calculation breakdown

End correction
9.027 mm
Geometry correction factor
1.5045
Effective neck length
38.027 mm
Opening pitch
100 mm
Depth for exact modelled target
305.42 mm
Absolute frequency error
89.6%
Compact wavelength screen
Within λ/8