Combined bearing load on a conveyor head
A conveyor head shaft has a fixed deep-groove bearing carrying a 5.8 kN radial reaction and 1.7 kN axial reaction.
Live results
Bearing load path- Dynamic load
- 5,713N
- L10
- 539.22million rev
- L10h
- 18,723h
- Modified life
- 10,185h
Service-life target
ReviewCalculated modified life falls below the entered service-hours target.
Editable case inputs
Calculation details
| Life exponent p | 3 |
|---|---|
| Reliability factor a₁ | 0.64 |
| Radial contribution X·Fr | 3,248 N |
| Axial contribution Y·Fa | 2,465 N |
| Modified-life target | 24,000 h |
| Hours above or below target | -13,814.7 h |
What to check
The axial term contributes to the equivalent dynamic load. Compare it with the radial term before evaluating a larger bearing.
Model & assumptions
Use catalog C, X and Y for the exact bearing and load arrangement. L10 is a population fatigue-life statistic at 90% reliability. Modified life uses the entered aISO. The service-hours target is a planning input.
Check minimum load, static capacity, lubrication, allowable speed and application limits separately. The 91–94% factors are interpolated between the ISO 281 values at 90% and 95%.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Combined bearing load on a conveyor head
P = X·Fr + Y·Fa · L10 = (C/P)ᵖ · Lnmh = a₁·aISO·L10h
Operating inputs
| Bearing element | Deep-groove ball |
|---|---|
| Running speed | 480 RPM |
| Dynamic rating C | 46,500 N |
| Service-hours target | 24,000 h |
| Radial load Fr | 5,800 N |
| Axial load Fa | 1,700 N |
| Radial factor X | 0.56 |
| Axial factor Y | 1.45 |
| Reliability | 95% |
| Operating factor aISO | 0.85 |
Results
| Dynamic load | 5,713 N |
|---|---|
| L10 | 539.22 million rev |
| L10h | 18,722.9 h |
| Modified life | 10,185.3 h |
| Life exponent p | 3 |
| Reliability factor a₁ | 0.64 |
| Radial contribution X·Fr | 3,248 N |
| Axial contribution Y·Fa | 2,465 N |
| Modified-life target | 24,000 h |
| Hours above or below target | -13,814.7 h |
Service-life target. Calculated modified life falls below the entered service-hours target.