RotorVibLab
Menu

Calculation methodology

The calculators use fixed engineering models with explicit measurement and operating assumptions. Select a tool to edit the base case, switch units or print its operating values and calculations.

Switching units preserves the physical inputs. The conversion uses the international inch (25.4 mm), the international pound (0.45359237 kg) and standard gravity (9.80665 m/s²). A temperature rise of 1 °C is a rise of 1.8 °F. Balance lb-in means lbm·in; torque uses lbf·in.

The ISO and API checks compare the entered case with the assumptions and limits shown. Use the governing project specification and measurements for acceptance decisions.

Bearing rating life

P = X·Fr + Y·Fa · L10 = (C/P)ᵖ · Lnmh = a₁·aISO·L10h

Use catalog C, X and Y for the exact bearing and load arrangement. L10 is a population fatigue-life statistic at 90% reliability. Modified life uses the entered aISO. The service-hours target is a planning input.

Check minimum load, static capacity, lubrication, allowable speed and application limits separately. The 91–94% factors are interpolated between the ISO 281 values at 90% and 95%.

Bearing fault frequencies

q = (Bd/Pd)·cos φ · FTF = fr·(1−q)/2 · BPFO/BPFI = Nb·fr·(1∓q)/2 · BSF = fr·Pd·(1−q²)/(2·Bd)

Use the geometry for one row, the inner-ring speed and a stationary outer ring. Search around the calculated orders and check harmonics and sidebands against a measured envelope spectrum. A rolling-element defect often appears at 2× BSF.

Bd must be strictly below Pd·cos φ. The kinematic model assumes rolling contact without slip. The spectrum shows calculated locations, and the marker height carries no amplitude information.

Rotor balance & trim

eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α

Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.

ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.

Vibration amplitude & zones

xpk = xpp/2 · vpk = 2πf·xpk · apk = (2πf)²·xpk · RMS = peak/√2

Enter one sinusoidal component to convert amplitude conventions. For zone screening, choose the RMS source and enter the maximum applicable measured broadband housing velocity at steady operation. Group 2 covers power above 15 kW up to 300 kW; group 1 covers larger machines. For electric machines, verify shaft-height criteria and support stiffness in the measurement direction.

This two-group calculator uses the ISO 20816-3:2022 velocity bands for groups 1 and 2. A value exactly at a boundary is shown in the higher zone. Apply the governing edition, machinery scope and measurement bandwidth on the job.

Isolator transmissibility

fn = √(k/m)/(2π) = √(g/δst)/(2π) · r = fd/fn · T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)]

Enter the supported mass for one mount and its vertical stiffness or loaded static deflection. For a single harmonic force, transmitted amplitude is T times the excitation. Negative isolation indicates amplification.

This single-mode model assumes a linear spring and viscous damping. At r = √2 the force ratio is unity. Include support flexibility, coupled modes and the start-up speed range when assessing a real installation.

Lateral critical speed

I = π(OD⁴−ID⁴)/64 · δii = mi·g·Cii · 1/ωcr² = 1/ωshaft² + Σ(δii/g)

For pin–pin support, place each disk strictly between the bearings. For a cantilever, measure from the clamp and place disks along the overhang. Zero disk mass omits that disk. The plot shows the static deflection shape under gravity, a visual proxy for the first bending mode.

API 610 12th ed. §6.9.1.2 screens the first dry critical of one- and two-stage pumps at 20% above maximum continuous speed. API 617 9th ed. §6.8.2.9 uses damped critical speed and AF; enter both from an independent response analysis for that comparison.

Shaft alignment

T+B = L+R · rim offset = signed TIR/2 · face slope = signed TIR/D · move = target−(offset + slope·distance)

Zero each dial at 12 o’clock and enter signed readings from the stationary-machine viewpoint looking toward the movable machine. For the first rim, positive (T−B)/2 is above and positive (L−R)/2 is right. The reverse indicator faces the opposite direction, so its radial readings have opposite polarity. For the face, (T−B)/D and (L−R)/D give slopes toward the movable machine.

Use the effective face sweep diameter or the spacing between the two rim planes. Correct for bracket sag before entry. Positive V adds shim thickness and positive H moves right. Growth mode sets the vertical cold target to stationary rise minus movable rise.

Torsional natural frequency

Jp = π(OD⁴−ID⁴)/32 · kt = G·Jp/L · fnt = √[kt·(1/J₁ + 1/J₂)]/(2π) · τ = Torque·r/Jp

Use polar mass inertias referred to the same shaft speed, a uniform shaft section and the effective elastic span. The node is L·J₂/(J₁+J₂) from the drive. Separation is the absolute difference between natural and excitation frequency divided by excitation frequency.

The specified margin is an engineering target at one operating point. Steady shear is calculated from transmitted torque. Assess the speed sweep, other inertias, fatigue and alternating torque for a complete drivetrain check.