Belt-driven supply fan bearing life
The catalog lists a deep-groove bearing with 28.6 kN dynamic capacity. A belt reaction puts 3.1 kN radial load on the drive-side bearing.
Live results
Bearing load path- Dynamic load
- 3,100N
- L10
- 785.26million rev
- L10h
- 8,964.1h
- Modified life
- 8,964.1h
Service-life target
ReviewCalculated modified life falls below the entered service-hours target.
Editable case inputs
Calculation details
| Life exponent p | 3 |
|---|---|
| Reliability factor a₁ | 1 |
| Radial contribution X·Fr | 3,100 N |
| Axial contribution Y·Fa | 0 N |
| Modified-life target | 9,000 h |
| Hours above or below target | -35.8542 h |
What to check
Set the axial load to zero and compare weighted load with the catalog rating. A belt-tension change has a cubic effect on basic life.
Model & assumptions
Use catalog C, X and Y for the exact bearing and load arrangement. L10 is a population fatigue-life statistic at 90% reliability. Modified life uses the entered aISO. The service-hours target is a planning input.
Check minimum load, static capacity, lubrication, allowable speed and application limits separately. The 91–94% factors are interpolated between the ISO 281 values at 90% and 95%.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Belt-driven supply fan bearing life
P = X·Fr + Y·Fa · L10 = (C/P)ᵖ · Lnmh = a₁·aISO·L10h
Operating inputs
| Bearing element | Deep-groove ball |
|---|---|
| Running speed | 1,460 RPM |
| Dynamic rating C | 28,600 N |
| Service-hours target | 9,000 h |
| Radial load Fr | 3,100 N |
| Axial load Fa | 0 N |
| Radial factor X | 1 |
| Axial factor Y | 0 |
| Reliability | 90% |
| Operating factor aISO | 1 |
Results
| Dynamic load | 3,100 N |
|---|---|
| L10 | 785.259 million rev |
| L10h | 8,964.15 h |
| Modified life | 8,964.15 h |
| Life exponent p | 3 |
| Reliability factor a₁ | 1 |
| Radial contribution X·Fr | 3,100 N |
| Axial contribution Y·Fa | 0 N |
| Modified-life target | 9,000 h |
| Hours above or below target | -35.8542 h |
Service-life target. Calculated modified life falls below the entered service-hours target.