Motor bearing life at 92% planning reliability

An electric motor is in a duty study that calls for 92% reliability between the listed 90% and 95% values.

Units
Edit inputs ↓

Live results

Bearing load path
L10
1,494.7million rev
L10h
8,415.9h
Modified life
8,284.7h
Radial sectionFrFaLoad zoneDynamic load contributionsRadial X·Fr3,250 NAxial Y·Fa178.5 NEquivalent P3,429 N

Service-life target

Review
ShortfallLife targetHeadroom

Calculated modified life falls below the entered service-hours target.

Editable case inputs

Bearing & duty
RPM
N
h
Forces & load factors
N
N
Life adjustment

Calculation details

Life exponent p3
Reliability factor a₁0.856
Radial contribution X·Fr3,250 N
Axial contribution Y·Fa178.5 N
Modified-life target9,500 h
Hours above or below target-1,215.35 h

What to check

The interpolated a₁ factor is 0.856. Compare modified life at 90%, 92% and 95% while keeping operating conditions fixed.

Model & assumptions

P = X·Fr + Y·Fa · L10 = (C/P)ᵖ · Lnmh = a₁·aISO·L10h

Use catalog C, X and Y for the exact bearing and load arrangement. L10 is a population fatigue-life statistic at 90% reliability. Modified life uses the entered aISO. The service-hours target is a planning input.

Check minimum load, static capacity, lubrication, allowable speed and application limits separately. The 91–94% factors are interpolated between the ISO 281 values at 90% and 95%.