Reverse-dial fan horizontal moves
Two opposing radial indicators span 150 mm. The front and rear feet sit 230 and 560 mm from the first plane.
Live results
Vertical & horizontal foot corrections- Front shim
- -0.004mm
- Rear shim
- 0.062mm
- Front move
- 0.086mm
- Rear move
- 0.152mm
Dial validity rule
Within screenBoth dial sets close within tolerance. Positive moves add shims or shift right from the stationary-machine viewpoint.
Editable case inputs
Calculation details
| Plane 1 vertical offset | 0.05 mm |
|---|---|
| Plane 1 horizontal offset | -0.04 mm |
| Vertical shaft slope | -0.2 mm/m |
| Horizontal shaft slope | -0.2 mm/m |
| First rim closure error | 0 µm |
| Opposite rim closure error | 0 µm |
| Front vertical cold target | 0 mm |
| Rear vertical cold target | 0 mm |
What to check
The second reading references the opposite bracket. Reverse its polarity before computing the slope between planes.
Model & assumptions
Zero each dial at 12 o’clock and enter signed readings from the stationary-machine viewpoint looking toward the movable machine. For the first rim, positive (T−B)/2 is above and positive (L−R)/2 is right. The reverse indicator faces the opposite direction, so its radial readings have opposite polarity. For the face, (T−B)/D and (L−R)/D give slopes toward the movable machine.
Use the effective face sweep diameter or the spacing between the two rim planes. Correct for bracket sag before entry. Positive V adds shim thickness and positive H moves right. Growth mode sets the vertical cold target to stationary rise minus movable rise.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Reverse-dial fan horizontal moves
T+B = L+R · rim offset = signed TIR/2 · face slope = signed TIR/D · move = target−(offset + slope·distance)
Operating inputs
| Dial method | Reverse-dial |
|---|---|
| Rim indicator span S | 150 mm |
| Front foot distance A | 230 mm |
| Rear foot distance B | 560 mm |
| Dial closure tolerance | 5 µm |
| Rim bottom · 6 o’clock | -100 µm |
| Rim left · 9 o’clock | -90 µm |
| Rim right · 3 o’clock | -10 µm |
| Second bottom · 6 o’clock | 40 µm |
| Second left · 9 o’clock | 90 µm |
| Second right · 3 o’clock | -50 µm |
| Vertical target method | Entered cold targets |
| Front vertical target | 0 µm |
| Rear vertical target | 0 µm |
| Front horizontal target | 0 µm |
| Rear horizontal target | 0 µm |
Results
| Front shim | -0.004 mm |
|---|---|
| Rear shim | 0.062 mm |
| Front move | 0.086 mm |
| Rear move | 0.152 mm |
| Plane 1 vertical offset | 0.05 mm |
| Plane 1 horizontal offset | -0.04 mm |
| Vertical shaft slope | -0.2 mm/m |
| Horizontal shaft slope | -0.2 mm/m |
| First rim closure error | 0 µm |
| Opposite rim closure error | 0 µm |
| Front vertical cold target | 0 mm |
| Rear vertical cold target | 0 mm |
Dial validity rule. Both dial sets close within tolerance. Positive moves add shims or shift right from the stationary-machine viewpoint.