RotorVibLab
Menu

Reverse-dial fan horizontal moves

Two opposing radial indicators span 150 mm. The front and rear feet sit 230 and 560 mm from the first plane.

Units
Edit inputs ↓

Live results

Vertical & horizontal foot corrections
Rear shim
0.062mm
Front move
0.086mm
Rear move
0.152mm
Reverse dialsS 150 mmVerticalAdd / removeHorizontalRight / leftFront A 230 mmRear B 560 mm

Dial validity rule

Within screen
CloseError limitRecheck

Both dial sets close within tolerance. Positive moves add shims or shift right from the stationary-machine viewpoint.

Editable case inputs

Alignment geometry
mm
mm
mm
µm
First rim readings · top = 0
µm
µm
µm
Second readings · top = 0
µm
µm
µm

Use axial face readings for rim-and-face, or opposite radial readings for reverse-dial.

Cold operating target
µm
µm
µm
µm

Calculation details

Plane 1 vertical offset0.05 mm
Plane 1 horizontal offset-0.04 mm
Vertical shaft slope-0.2 mm/m
Horizontal shaft slope-0.2 mm/m
First rim closure error0 µm
Opposite rim closure error0 µm
Front vertical cold target0 mm
Rear vertical cold target0 mm

What to check

The second reading references the opposite bracket. Reverse its polarity before computing the slope between planes.

Model & assumptions

T+B = L+R · rim offset = signed TIR/2 · face slope = signed TIR/D · move = target−(offset + slope·distance)

Zero each dial at 12 o’clock and enter signed readings from the stationary-machine viewpoint looking toward the movable machine. For the first rim, positive (T−B)/2 is above and positive (L−R)/2 is right. The reverse indicator faces the opposite direction, so its radial readings have opposite polarity. For the face, (T−B)/D and (L−R)/D give slopes toward the movable machine.

Use the effective face sweep diameter or the spacing between the two rim planes. Correct for bracket sag before entry. Positive V adds shim thickness and positive H moves right. Growth mode sets the vertical cold target to stationary rise minus movable rise.

Methodology and references ↗