Low-speed cage frequency in CPM
A drying drum runs at 95 RPM. The cage line is easier to compare with a low-frequency trace using cycles per minute.
Live results
Bearing geometry & order spectrum- BPFO
- 9.9774Hz
- BPFI
- 13.773Hz
- BSF
- 4.7389Hz
- FTF
- 0.66516Hz
Bearing geometry
Within screenThe diameter inequality is satisfied. Use the markers as search frequencies in a measured spectrum.
Editable case inputs
Calculation details
| Shaft rotational frequency | 1.58333 Hz |
|---|---|
| Shaft rotational frequency | 95 CPM |
| Strict element-diameter ceiling | 126.63 mm |
| Diameter below ceiling | 105.63 mm |
Order and harmonic markers
| Line | Hz | CPM | Order | 2× Hz | 2× CPM | 2× order |
|---|---|---|---|---|---|---|
| BPFO | 9.9774 | 598.64 | 6.3015 | 19.955 | 1,197.3 | 12.603 |
| BPFI | 13.773 | 826.36 | 8.6985 | 27.545 | 1,652.7 | 17.397 |
| BSF | 4.7389 | 284.33 | 2.993 | 9.4778 | 568.67 | 5.986 |
| FTF | 0.66516 | 39.91 | 0.4201 | 1.3303 | 79.819 | 0.8402 |
What to check
Use FTF as the search centre. Low-speed slip can shift an observed line away from the no-slip prediction.
Model & assumptions
Use the geometry for one row, the inner-ring speed and a stationary outer ring. Search around the calculated orders and check harmonics and sidebands against a measured envelope spectrum. A rolling-element defect often appears at 2× BSF.
Bd must be strictly below Pd·cos φ. The kinematic model assumes rolling contact without slip. The spectrum shows calculated locations, and the marker height carries no amplitude information.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Low-speed cage frequency in CPM
q = (Bd/Pd)·cos φ · FTF = fr·(1−q)/2 · BPFO/BPFI = Nb·fr·(1∓q)/2 · BSF = fr·Pd·(1−q²)/(2·Bd)
Operating inputs
| Pitch diameter Pd | 129 mm |
|---|---|
| Element diameter Bd | 21 mm |
| Contact angle φ | 11 ° |
| Elements per row Nb | 15 |
| Running speed | 95 RPM |
Results
| BPFO | 9.97738 Hz |
|---|---|
| BPFI | 13.7726 Hz |
| BSF | 4.73891 Hz |
| FTF | 0.665159 Hz |
| Shaft rotational frequency | 1.58333 Hz |
| Shaft rotational frequency | 95 CPM |
| Strict element-diameter ceiling | 126.63 mm |
| Diameter below ceiling | 105.63 mm |
Order and harmonic markers
| Line | Hz | CPM | Order | 2× Hz | 2× CPM | 2× order |
|---|---|---|---|---|---|---|
| BPFO | 9.9774 | 598.64 | 6.3015 | 19.955 | 1,197.3 | 12.603 |
| BPFI | 13.773 | 826.36 | 8.6985 | 27.545 | 1,652.7 | 17.397 |
| BSF | 4.7389 | 284.33 | 2.993 | 9.4778 | 568.67 | 5.986 |
| FTF | 0.66516 | 39.91 | 0.4201 | 1.3303 | 79.819 | 0.8402 |
Bearing geometry. The diameter inequality is satisfied. Use the markers as search frequencies in a measured spectrum.