Velocity RMS
2.3mm/s RMS
Accel. peak
0.062521g pk
Velocity zone
Zone B
One sinusoidal cycle30 HzRMS velocity bandsmm/s RMSABCD1.42.84.5Measured overall2.3 mm/s RMS

ISO 20816-3 velocity bands

Within screen
Zone AZone BZone CZone D

Zone B uses the entered overall RMS reading.

Operating inputs

Harmonic signal
mm/s RMS
Hz
Severity assessment
mm/s RMS

Calculation details

Tone frequency30 Hz
Tone frequency1,800 CPM
Peak velocity3.25269 mm/s pk
RMS acceleration0.0442088 g RMS
RMS velocity used for zone2.3 mm/s RMS
A/B boundary1.4 mm/s RMS
B/C boundary2.8 mm/s RMS
C/D boundary4.5 mm/s RMS
Headroom to B/C0.5 mm/s RMS

Model & assumptions

xpk = xpp/2 · vpk = 2πf·xpk · apk = (2πf)²·xpk · RMS = peak/√2

Enter one sinusoidal component to convert amplitude conventions. For zone screening, choose the RMS source and enter the maximum applicable measured broadband housing velocity at steady operation. Group 2 covers power above 15 kW up to 300 kW; group 1 covers larger machines. For electric machines, verify shaft-height criteria and support stiffness in the measurement direction.

This two-group calculator uses the ISO 20816-3:2022 velocity bands for groups 1 and 2. A value exactly at a boundary is shown in the higher zone. Apply the governing edition, machinery scope and measurement bandwidth on the job.