Mount tuning
30 mm f/4 guide scope on a 700 mm imaging rig
The mini guide setup gives about 4.98″/px, against 1.11″/px for imaging. The resulting 1:4.50 ratio is just coarser than the worksheet’s 1:4 guide.
Setup
- Main focal length
- 700 mm
- Main-camera pixel pitch
- 3.76 µm
- Guide focal length
- 120 mm
- Guide-camera pixel pitch
- 2.9 µm
- Guide-camera binning
- 1×1
- RA guiding RMS
- 0.55 ″
- Dec guiding RMS
- 0.4 ″
- Round-star budget
- 0.7 imaging px
- Unguided RA periodic error
- 18 ″ peak-to-peak
- Worm period
- 480 s
- Polar alignment error
- 3 ′
- Guide-star declination
- 35 °
- Guide star to farthest corner
- 0.8 °
- Sub-exposure time
- 5 min
Results
Correct the marked inputs to update the results.
- Main : guide scale
- 1 : 4.5
- Total guiding RMS
- 0.68″
- RMS on imaging sensor
- 0.614 px
- Round-star margin
- 0.095″
The guide scale is coarser than the 1:4 rule. Guiding RMS is within your chosen motion budget.
More results
- Main image scale
- 1.108 ″/px
- Guide image scale
- 4.985 ″/px
- Round-star budget
- 0.776″
- Unguided worm RMS
- 6.364″
- Worst worm swing per sub
- 18″
- Worst unguided Dec drift per sub
- 3.938″
- Guided field rotation angle
- 4.807″
- Rotation trail at far corner
- 0.067″
- Rotation trail on imaging sensor
- 0.061 px
Calculation steps
- Main and guide scale 206.265 × pitch × binning ÷ focal length gives 1.108″/px and 4.985″/px
- RMS and margin √(0.55² + 0.4²) = 0.68″. 0.7 px × main scale − RMS = 0.095″
- Periodic error 18″ peak-to-peak ÷ (2√2) = 6.364″ RMS for a sine wave
- Polar drift and rotation 0.2625 × 3′ × 5 min ≈ 3.938″ maximum Dec drift. Divide by cos(35°) for rotation, then multiply by sin(0.8°) = 0.067″ of corner trail.
In the field
If a sharp, well-exposed guide star and rigid mounting already give good main-camera frames, use your logs and images to decide whether a longer guide scope earns its weight.
Compare setups
200 mm guide focal length
| Measure | Example | Alternative |
|---|---|---|
| Main : guide scale | 1 : 4.5 | 1 : 2.7 |
| Guide image scale | 4.985 ″/px | 2.991 ″/px |
| Total guiding RMS | 0.68″ | 0.68″ |
| RMS on imaging sensor | 0.614 px | 0.614 px |
| Round-star margin | 0.095″ | 0.095″ |
Model assumptions
The main:guide pixel-scale rule of 1:4 and the adjustable motion budget are guidelines. Seeing, differential flexure, guiding cadence and the direction of tracking error also affect star shape.
The periodic estimate treats unguided RA motion as a single sine wave, independent of the measured guiding RMS. Drift and rotation use worst-orientation small-angle geometry on an equatorial mount. The rotation estimate assumes the guide star is held fixed.
Frequently asked questions
Does a 30 mm f/4 mini guide scope hit a 1:4 ratio here?
At 120 mm and 2.9 µm, the guide scale is about 4.50 times coarser than the chosen main scale.
Will the longer guide scope automatically lower the measured 0.68″ RMS?
The scale ratio improves. Actual guiding RMS still depends on seeing, signal to noise, mount behavior and flexure.