Optical train

60 mm f/6 refractor: 0.5× reducer on a small sensor

The idealized 0.5× setup brings f/6 down to f/3. A small sensor can avoid some badly corrected corners, but it still sees the illumination pattern of the actual image circle.

Setup

Telescope
Optical accessory
Enter 1 for native optics or the measured factor at your working spacing.

Results

Effective focal length
180 mm
Effective f-ratio
f/3
Photographic speed
4×
Exposure time factor
0.25×

A reference 60 s exposure becomes about 15 s for the same extended-source electrons per pixel.

Native & modified light cones
Native & modified light cones RELATIVE LIGHT-CONE LENGTHNative360 mmReducer180 mm

More results

Native f-ratio
f/6
Small-angle field width factor
2×
Optical configuration
Reducer

Calculation steps

  1. Modified focal length 360 mm × 0.5 = 180 mm
  2. Working f-ratio Modified focal length ÷ 60 mm = f/3
  3. Photographic speed (native f-ratio ÷ working f-ratio)² = 4×
  4. Exposure time factor 1 ÷ photographic speed = 0.25×

In the field

Take a flat and solve a short star field. If the usable frame is too small, compare a milder factor before deciding on the mosaic plan.

Open the general calculator

Compare setups

0.8× reduction

MeasureExampleAlternative
Effective focal length180 mm288 mm
Effective f-ratiof/3f/4.8
Photographic speed4×1.563×
Exposure time factor0.25×0.64×
Small-angle field width factor2×1.25×

Model assumptions

Exposure scaling follows the square of the f-ratio for uniform extended surface brightness at the same pixel pitch and throughput. Stars, clipping, filter transmission and read noise can behave differently.

Rated multipliers assume the intended optical spacing. Scope focus position can shift the actual focal length. Seeing still affects detail at the new image scale. The cone drawing compares focal planes schematically.

Frequently asked questions

How much wider is the field at 180 mm than at 360 mm?

Roughly twice as wide in the small-angle limit. Actual usable width also depends on vignetting and correction.

Why can the f/3 result overstate a 0.5× reducer’s practical gain?

Transmission, vignetting and the true working factor can reduce the ideal fourfold speed increase.

Related worked examples