Camera matching
C8 at 2,032 mm: binning 3.76 µm pixels in 2.5″ seeing
Native pixels put more than six samples across the 2.5″ seeing disk. A 3×3 output puts about 2.18 samples across it, if your acquisition or processing supports that mode.
Setup
- Focal length
- 2032 mm
- Pixel pitch
- 3.76 µm
- Pixel binning
- 1×1
- Seeing FWHM
- 2.5 ″
- Active sensor width
- 23.5 mm
- Active sensor height
- 15.7 mm
Results
Correct the marked inputs to update the results.
- Image scale
- 0.382 ″/px
- Sampling
- Oversampled
- Pixels across FWHM
- 6.55 px
- Sensor field
- 0.66 × 0.44°
2.5″ seeing is 6.55 pixels wide. This worksheet uses 2–3 pixels as the practical target.
More results
- Sensor field in arcminutes
- 39.8 × 26.6′
- Effective pixel pitch
- 3.76 µm
- Ideal finer limit
- 0.833 ″/px
- Ideal coarser limit
- 1.25 ″/px
Calculation steps
- Image scale 206.265 × 3.76 × 1 ÷ 2032 = 0.382″/px
- Seeing sampling 2.5″ ÷ image scale = 6.55 px across FWHM
- Field width 2 arctan(23.5 ÷ (2 × 2032)) = 0.66°
- Field height 2 arctan(15.7 ÷ (2 × 2032)) = 0.44°
In the field
Use measured stellar profiles from calibrated subs. Some autofocus or guiding tools depend on their own binning settings.
Compare setups
3×3 output binning
| Measure | Example | Alternative |
|---|---|---|
| Image scale | 0.382 ″/px | 1.145 ″/px |
| Sampling | Oversampled | Ideal |
| Pixels across FWHM | 6.55 px | 2.18 px |
| Effective pixel pitch | 3.76 µm | 11.28 µm |
| Sensor field | 0.66 × 0.44° | 0.66 × 0.44° |
Model assumptions
The practical sampling window is 2–3 pixels across the seeing FWHM. This heuristic treats the seeing disk as the dominant blur and approximates detector sampling near the optical axis.
Binning changes the scale per output pixel but preserves the field when you keep the full active sensor. FOV uses a rectilinear projection and the active dimensions.
Frequently asked questions
Would 2×2 already reach the 2–3 px window on the native C8 at 2.5″ seeing?
It gives about 3.27 px per FWHM, just above this planning window. 3×3 gives about 2.18 px.
Why is a measured C8 focal length useful for binning decisions?
The moving mirror and accessory spacing can shift the scale. Plate solving removes that uncertainty.