Target planning
M51 Whirlpool at 1,200 mm vs 2,032 mm on IMX533
The worked 11′ × 7′ core pair occupies roughly a third of the 1,200 mm frame width. Longer focal length grows the relative fill while making the seeing and guiding budgets harder.
Setup
- Deep-sky or lunar target
- M51 · Whirlpool Galaxy
- Focal length
- 1200 mm
- Active sensor width
- 11.31 mm
- Active sensor height
- 11.31 mm
- Target angle from sensor width
- 0 °
- Columns × rows
- 1×1 · single frame
- Panel overlap
- 15 %
- Integration per panel
- 5 h
- Clear time per night
- 4 h
- Time kept after overhead
- 80 %
Results
Correct the marked inputs to update the results.
- Single-frame field
- 32.4 × 32.4′
- Target fill in one frame
- 34% × 21.6%
- Mosaic field
- 32.4 × 32.4′
- Clear session time
- 6.25 h
M51 · Whirlpool Galaxy fits in one frame. Allow 2 clear nights at this time budget.
More results
- Rotated target extent
- 11 × 7′
- Target fill on mosaic
- 34% × 21.6%
- Single-frame fit
- Fits
- Mosaic fit
- Fits
- Panel count
- 1
- Net integration
- 5 h
- Clear nights
- 2
Calculation steps
- Single-frame field 2 arctan(sensor side ÷ (2 × 1200)) gives 32.4 × 32.4′
- Target fill Rotated target extent ÷ frame extent per axis = 34% × 21.6%
- Mosaic footprint Scale sensor-plane axes by 1 + (panel count on axis − 1) × 0.85 before converting to angles
- Clear time 1 × 5 h ÷ 80% usable time = 6.25 h
In the field
Decide how much nearby background you want. Compare the sampling and guiding tools before trading margin for a tighter native framing.
Compare setups
Native 2,032 mm framing
| Measure | Example | Alternative |
|---|---|---|
| Single-frame field | 32.4 × 32.4′ | 19.1 × 19.1′ |
| Target fill in one frame | 34% × 21.6% | 57.5% × 36.6% |
| Mosaic field | 32.4 × 32.4′ | 19.1 × 19.1′ |
| Target fill on mosaic | 34% × 21.6% | 57.5% × 36.6% |
| Clear session time | 6.25 h | 6.25 h |
Model assumptions
Target sizes are rounded planning extents. A rotated ellipse estimates the width and height of the target and the Moon is fixed at a representative 0.5°. Faint emission and lunar distance can change the useful size.
Panel overlap is measured along each sensor axis in a shared rectilinear projection. Check wide fields with a plate-solving planner. The time budget uses net integration divided by the chosen fraction of usable time. Seeing, transparency and sky brightness determine how much signal that time gives you.
Frequently asked questions
Does the 11′ M51 target fill half of the native 2,032 mm square field?
It fills about 57% of the frame width using the sample 11.31 mm sensor.
Is the worksheet’s M51 extent intended to include all tidal structures?
It is a nominal planning size for the bright system. Faint extended structure can merit a wider field.