Worked example

Best Mix for a Wreck with a 1.2 ATA Target

A wreck deck at 120 ft illustrates how a lower oxygen target changes the theoretical candidate. Keep water type and depth fixed to isolate that choice.

Inputs

ft
ATA

Results

Live calculation
Whole-percent candidate
25%
Rounded down from the theoretical fraction.
Theoretical oxygen
25.88%
Candidate PPO₂ at depth
1.159ATA
Candidate equivalent air depth
112.3ft
1.6 ATA contingency depth
178.2ft
A comparison ceiling, rounded down.
Best-mix curveTheoretical oxygen fraction 25.88% at 120 ft. Best-mix curveTHEORETICAL O₂ · %0040408080120120160160DEPTH · ft21% air25.88% exact · 25% whole

Work through this example

Lowering PPO₂ at the same depth lowers the oxygen fraction. The 1.6 ATA contingency line remains a separate comparison for the rounded candidate.

Try it. Try 1.3 and 1.4 ATA. Observe the candidate PPO₂ at 120 ft as the whole percentage changes.

How the calculation works

Invert the pressure equation

Theoretical O₂ percent = 100 × target PPO₂ ÷ ambient pressure. Ambient pressure uses a 33 ft salt-water head per ATA or a 2.5% larger freshwater head.

Round the oxygen fraction down

Floor the candidate to a whole percentage and cap it at 100%. When the fraction falls below 21%, the tool has no enriched-air candidate. Apply the candidate fraction to the EAD and 1.6 ATA depth equations.

References

Questions & answers

How does a 1.2 ATA target change the 120 ft mix?

It reduces the oxygen fraction the calculation permits at that pressure. Compare both the exact and whole-percent values.

Why track the working target and contingency depth separately on a wreck?

They answer different questions. The working target sets the candidate while the contingency reference shows a separate oxygen ceiling.