Worked example
Best Mix for a 30 m Freshwater Quarry
At a low-elevation quarry, a team compares oxygen candidates for a 30 m maximum and a 1.3 ATA target.
Inputs
Results
Live calculationFix the highlighted inputs to view the results and diagram.
- Whole-percent candidate
- 33%
- Rounded down from the theoretical fraction.
- Theoretical oxygen
- 33.25%
- Candidate PPO₂ at depth
- 1.29ATA
- Candidate equivalent air depth
- 23.9m
- 1.6 ATA contingency depth
- 39.6m
- A comparison ceiling, rounded down.
Work through this example
Water density determines the ambient pressure. The exact fraction may move when you change density even if the rounded integer stays the same.
Try it. Change water type and compare the exact results before checking the whole-percent candidate.
How the calculation works
Invert the pressure equation
Theoretical O₂ percent = 100 × target PPO₂ ÷ ambient pressure. Ambient pressure uses a 33 ft salt-water head per ATA or a 2.5% larger freshwater head.
Round the oxygen fraction down
Floor the candidate to a whole percentage and cap it at 100%. When the fraction falls below 21%, the tool has no enriched-air candidate. Apply the candidate fraction to the EAD and 1.6 ATA depth equations.
References
More worked examples
Questions & answers
What is held fixed when the 30 m quarry example switches water type?
The calculator keeps 30 m and 1.3 ATA fixed. It changes the hydrostatic pressure model.
Why can two best-mix settings show the same whole percent?
Rounding down groups a range of exact fractions into the same integer. Inspect the exact result to see the difference.