Gas supply
Scuba Tank Volume, Rock Bottom & Rule of Thirds Calculator
Estimate free gas, a two-diver ascent reserve and a turn pressure for a single cylinder or identical manifolded twins.
Inputs
Results
Live calculationFix the highlighted inputs to view the results and diagram.
- Adjusted turn pressure
- 2,000psi
- Rounded up in the selected units.
- Starting free gas
- 77.4ft³
- Gas above effective reserve
- 51.6ft³
- Two-diver ascent gas
- 22.1ft³
- Rock-bottom pressure
- 858psi
- Rounded up in the selected units.
- Effective reserve floor
- 1,000psi
- Rounded up in the selected units.
- Turn rule before reserve check
- 2,000psi
How the calculation works
Model an open-water ascent
Two divers each breathe the entered stressed RMV. Budget one minute at depth, then ascend at 9 m/min with a modeled three-minute pause at 5 m when the starting depth is at least 5 m. Each ascent leg uses the average pressure of its endpoints. Verify a complete team plan for the actual profile and any overhead or decompression.
Protect the effective reserve
Take the highest of the chosen floor, ascent gas in gauge pressure, and one-third of start for thirds. The turn is the higher of the rule baseline (two-thirds of start or half + 200 psi) and halfway between start and the effective floor. Free gas scales linearly with cylinder pressure.
References
Worked examples
Questions & answers
How can rock bottom move the turn above two-thirds?
When the ascent needs more than one-third of the starting gas, preserving that larger reserve means using less gas on the outbound leg.
What does half plus 200 psi mean on the gauge?
Its baseline is half the starting pressure plus 200 psi, equivalent to about 13.8 bar. The calculator raises the result if an equal return leg would dip into the effective reserve.
How does a manifold change the rock-bottom pressure?
Identical manifolded twins hold twice the free gas per psi of one cylinder. Independent cylinders need a separate usable-gas and failure analysis.