Worked example · ASCE/SEI 7-16 §§11.4–11.6, 12.8

Warehouse with a heavy mezzanine

A partial mezzanine is lower than the roof and carries most of the effective seismic weight. The height and weight schedule differs markedly from the uniform default.

Calculation sheet
Export

Inputs

Hazard and occupancy
g
g
Structure
ft
kip
Period and level schedule

A zero elevation uses uniform spacing. The top level is fixed at 100%. The worksheet apportions W using the relative weights.

Period parameters

Use the coefficient for hₙ in feet in either display mode.

Enter 0 to use Table 12.8-1.

s

Enter 0 to use Tₐ.

s
Level 1
%
Level 2
BASE SHEAR
189.073kip
RESPONSE Cₛ
0.0727
PERIOD T
0.481s
DESIGN CAT.
D

Story force elevationFₓ peak 98.27 kiphₙ 35 ftDesign response spectrumSₐ (g)T = 0.48 s0.62008.8 s5% referenceStrength period
Level-force vectors and the two-period design spectrum. The active point uses the strength period.

Calculation detail

Site coefficients Fₐ / Fᵥ
1.224 / 1.5
Mapped site response Sᴍₛ
0.845 g
Mapped site response Sᴍ₁
0.315 g
Short-period design Sᴅₛ
0.563 g
One-second design Sᴅ₁
0.21 g
Importance factor Iₑ
1
Approximate Tₐ
0.481 s
Upper period CᵤTₐ
0.717 s
Period cap on Cₛ
0.07272
General minimum Cₛ
0.02477
High-S₁ minimum Cₛ
0
Governing Cₛ check
Period-based cap
Distribution exponent k
1
Story force schedule
LevelElevation (ft)Weight (kip)CᵥₓFₓ (kip)Vₓ (kip)
114.71,787.50.480290.8021189.0727
235812.50.519898.270798.2707

How the calculation works

Read this example

Open the level schedule to compare the relative weights. The force share depends on both weight and elevation.

Preset result: BASE SHEAR 189.073 kip.

From mapped hazard to the design spectrum

Interpolate Fₐ and Fᵥ using the ASCE 7-16 Supplement 3 tables. Default Site Class D uses a minimum Fₐ of 1.2. Sᴍₛ = FₐSₛ and Sᴍ₁ = FᵥS₁. Multiply each by 2/3 for the design ordinates. The design category uses the more severe result of the two SDC tables and the high-S₁ rule. Class B values assume measured rock velocity.

Strength period and governing coefficient

Tₐ = Cₜhₙˣ. The entered model period is capped by CᵤTₐ for strength. Cₛ starts at Sᴅₛ/(R/Iₑ), uses the smaller applicable upper value from Eq. 12.8-3 or 12.8-4, and then applies both lower bounds in Eqs. 12.8-5 and 12.8-6.

Level forces and shears

V = CₛW. Each level receives a share proportional to wₓhₓᵏ. k rises linearly from 1 at 0.5 s to 2 at 2.5 s. A story shear is the sum of its level force and all level forces above.

Site-specific screening and Supplement 3

For Site Class D at S₁ ≥ 0.2 g the selected exception increases Sᴍ₁ by 50%. For Site Class E at Sₛ ≥ 1.0 g or S₁ ≥ 0.2 g the selected ELF exception uses Eq. 12.8-2 for all periods, subject to the Cₛ minimums. Confirm that the exception is applicable before selecting it.

Design scope

Verify ELF eligibility, approved hazard data, system coefficients and the adopted supplement before using these loads. Site-specific ground motion analysis requires separate hazard and geotechnical data.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • ASCE 7-16 Supplement 3https://ascelibrary.org/doi/pdf/10.1061/9780784414248.sup3
  • ASCE Hazard Toolhttps://www.asce.org/publications-and-news/asce-hazard-tool/
  • FEMA P-1051 design exampleshttps://www.fema.gov/sites/default/files/2020-07/fema_nehrp-seismic-provisions-examples_p-1051_20160701.pdf