Worked example · Simple-span statics · ASCE 7-16 §12.10 context

Long and narrow loading canopy

The canopy exceeds the 4:1 aspect screen and develops a comparatively large shear flow along its narrow wall line.

Calculation sheet
Export

Inputs

Diaphragm loading and geometry
plf
ft
ft
Collector openings

Measure along the supporting wall from one end. A zero gap length removes that opening.

Wall gap 1
ft
ft
Wall gap 2
ft
ft
Wall gap 3
ft
ft
UNIT SHEAR
610.435plf
CHORD FORCE
16.482kip
PEAK DRAG
3.663kip
ASPECT L/B
4.7
Proportion: Above 4:1

Compare this geometry with the limits and fastening details for the specific diaphragm assembly.

Diaphragm plan & chordsCompression chordTension chordL 108 ftB 23 ftShear and collector profileSigned span shear±14.04 kipCollector drag at gaps3.66 kip023 ft
Plan and load diagrams for a uniform span. The collector line plots the drag that builds across each opening.

Calculation detail

Reaction at each wall
14.04 kip
Maximum diaphragm moment
379.08 kip·ft
Tension chord
16.482 kip
Compression chord
16.482 kip
Collector openings
GapStart (ft)End (ft)Drag (kip)
211173.6626

How the calculation works

Read this example

Review the position of support lines or an appropriate engineered diaphragm model before detailing collectors.

Preset result: UNIT SHEAR 610.435 plf.

Find the support and chord forces

Uniform line load gives V = wL/2 and M = wL²/8. The peak diaphragm unit shear is V/B. Treat the tension and compression chords as a force couple separated by B, giving M/B in each chord.

Follow the shear across wall openings

A gap interrupts the uniform transfer line. The transferred drag across an isolated opening is unit shear times its length. The profile resets at the next pier in this model.

Read the aspect ratio as a screen

L/B is compared with 3:1 and 4:1 for early layout review. The actual permitted ratio depends on the chosen system and applicable material standard.

Design scope

Provide the governing design line load. Check collector continuity, overstrength, pier capacity, material limits, flexible or rigid distribution, and force transfer around openings separately.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • FEMA P-1051 design exampleshttps://www.fema.gov/sites/default/files/2020-07/fema_nehrp-seismic-provisions-examples_p-1051_20160701.pdf

More diaphragm, chords & collectors examples