Worked example · Simple-span statics · ASCE 7-16 §12.10 context

Narrow retail diaphragm with a 4:1 ratio

A narrow retail bay sits at the edge of the 4:1 layout band. A deep opening leaves a short pier on either side.

Calculation sheet
Export

Inputs

Diaphragm loading and geometry
plf
ft
ft
Collector openings

Measure along the supporting wall from one end. A zero gap length removes that opening.

Wall gap 1
ft
ft
Wall gap 2
ft
ft
Wall gap 3
ft
ft
UNIT SHEAR
810plf
CHORD FORCE
24.3kip
PEAK DRAG
13.77kip
ASPECT L/B
4
Proportion: Between 3:1 and 4:1

Compare this geometry with the limits and fastening details for the specific diaphragm assembly.

Diaphragm plan & chordsCompression chordTension chordL 120 ftB 30 ftShear and collector profileSigned span shear±24.3 kipCollector drag at gaps13.77 kip030 ft
Plan and load diagrams for a uniform span. The collector line plots the drag that builds across each opening.

Calculation detail

Reaction at each wall
24.3 kip
Maximum diaphragm moment
729 kip·ft
Tension chord
24.3 kip
Compression chord
24.3 kip
Collector openings
GapStart (ft)End (ft)Drag (kip)
162313.77

How the calculation works

Read this example

Increase the span slightly to see the screening band change. The assembly-specific ratio still governs the design.

Preset result: UNIT SHEAR 810 plf.

Find the support and chord forces

Uniform line load gives V = wL/2 and M = wL²/8. The peak diaphragm unit shear is V/B. Treat the tension and compression chords as a force couple separated by B, giving M/B in each chord.

Follow the shear across wall openings

A gap interrupts the uniform transfer line. The transferred drag across an isolated opening is unit shear times its length. The profile resets at the next pier in this model.

Read the aspect ratio as a screen

L/B is compared with 3:1 and 4:1 for early layout review. The actual permitted ratio depends on the chosen system and applicable material standard.

Design scope

Provide the governing design line load. Check collector continuity, overstrength, pier capacity, material limits, flexible or rigid distribution, and force transfer around openings separately.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • FEMA P-1051 design exampleshttps://www.fema.gov/sites/default/files/2020-07/fema_nehrp-seismic-provisions-examples_p-1051_20160701.pdf

More diaphragm, chords & collectors examples