Worked example · ASCE 7-16 Chapter 18 · Eurocode 8 · Den Hartog

First lateral mode of an office frame

A representative office-frame mode uses a known stiffness and modal mass. The 5% reference and 5% modified curves coincide.

Calculation sheet
Export

Inputs

Primary oscillator
kip·s²/ft
kip/ft
%
Spectrum and absorber
g
g
s
%
PERIOD Tₙ
0.971s
FREQUENCY fₙ
1.029Hz
DAMPED Sₐ
0.474g
PSEUDO Sᴅ
4.37in

Primary frame and tuned massmmᴅk 410 kip/ftμ 3.5%Modified response spectrumSₐ (g)T = 0.97 s1.05008.8 s5% reference5% damping
The oscillator drawing identifies the primary and secondary masses. The chart compares 5% damping with the selected modifier.

Calculation detail

Modal mass
9.8 kip·s²/ft
Undamped ωₙ
6.468 rad/s
Damped ωᴅ
6.46 rad/s
5% Sₐ at Tₙ
0.474 g
Pseudo-velocity Sᵥ
2.356 ft/s
ASCE damping table B
1
ASCE B at Tₙ
1
EC8 modifier η
1
TMD modal mass
0.343 kip·s²/ft
TMD frequency ratio
0.9662
TMD frequency
0.995 Hz
TMD spring stiffness
13.396 kip/ft
TMD damping ζopt
11.261%
Fixed-point peak Hmax
7.6251

How the calculation works

Read this example

Increase damping to observe how the spectral displacement changes while the undamped period remains the same.

Preset result: PERIOD Tₙ 0.971 s.

Calculate the primary mode

ωₙ = √(k/m), Tₙ = 2π/ωₙ, and ωᴅ = ωₙ√(1 − ζ²). With Sₐ as a fraction of g, use Sᵥ = Sₐg/ωₙ and Sᴅ = Sₐg/ωₙ² for pseudo-velocity and displacement.

Compare damping treatments

The ASCE effective damping coefficient B is interpolated from Table 18.7-1 and divides the curve by B. Below T₀, interpolate the divisor from 1 at zero period to the table value at T₀. The EC8 multiplier is max(0.55, √[10/(5 + ζ%)]), applied here to the entered two-period ASCE shape for comparison.

Tune a secondary mass

Den Hartog harmonic-force tuning uses fopt = 1/(1 + μ), kᴅ = μkfopt² and ζopt = √[3μ/(8(1 + μ))]. Hmax = √(1 + 2/μ) is the classical fixed-point estimate for the undamped primary benchmark.

Design scope

A single linear mode and a preliminary harmonic TMD estimate. The entered primary damping modifies the response spectrum and damped natural frequency. A project-specific TMD requires excitation, stroke, tolerances, and damping-system analysis.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • JRC Eurocode 8 worked exampleshttps://eurocodes.jrc.ec.europa.eu/sites/default/files/2022-06/EC8_Seismic_Design_of_Buildings-Worked_examples-main_only.pdf
  • Marian and Giaralis, classical TMD comparisonhttps://openaccess.city.ac.uk/id/eprint/17700/7/Marian%20and%20Giaralis_SSS_revised%20paper_ACCEPTED.pdf

More sdof spectrum & tuned mass examples