Worked example · ASCE 7-16 Chapter 18 · Eurocode 8 · Den Hartog

Tower using effective modal weight

The structural model reports an effective modal weight instead of inertial mass. The worksheet divides weight by standard gravity internally.

Calculation sheet
Export

Inputs

Primary oscillator
kip
kip/ft
%
Spectrum and absorber
g
g
s
%
PERIOD Tₙ
3.173s
FREQUENCY fₙ
0.315Hz
DAMPED Sₐ
0.166g
PSEUDO Sᴅ
16.378in

Primary frame and tuned massmmᴅk 390 kip/ftμ 4.5%Modified response spectrumSₐ (g)T = 3.17 s1008.8 s5% reference7% damping
The oscillator drawing identifies the primary and secondary masses. The chart compares 5% damping with the selected modifier.

Calculation detail

Modal mass
99.459 kip·s²/ft
Undamped ωₙ
1.98 rad/s
Damped ωᴅ
1.975 rad/s
5% Sₐ at Tₙ
0.18 g
Pseudo-velocity Sᵥ
2.703 ft/s
ASCE damping table B
1.08
ASCE B at Tₙ
1.08
EC8 modifier η
0.9129
TMD modal mass
4.476 kip·s²/ft
TMD frequency ratio
0.9569
TMD frequency
0.302 Hz
TMD spring stiffness
16.071 kip/ft
TMD damping ζopt
12.708%
Fixed-point peak Hmax
6.7412

How the calculation works

Read this example

Compare the calculated period with a mode analysis using the same modal weight and stiffness.

Preset result: PERIOD Tₙ 3.173 s.

Calculate the primary mode

ωₙ = √(k/m), Tₙ = 2π/ωₙ, and ωᴅ = ωₙ√(1 − ζ²). With Sₐ as a fraction of g, use Sᵥ = Sₐg/ωₙ and Sᴅ = Sₐg/ωₙ² for pseudo-velocity and displacement.

Compare damping treatments

The ASCE effective damping coefficient B is interpolated from Table 18.7-1 and divides the curve by B. Below T₀, interpolate the divisor from 1 at zero period to the table value at T₀. The EC8 multiplier is max(0.55, √[10/(5 + ζ%)]), applied here to the entered two-period ASCE shape for comparison.

Tune a secondary mass

Den Hartog harmonic-force tuning uses fopt = 1/(1 + μ), kᴅ = μkfopt² and ζopt = √[3μ/(8(1 + μ))]. Hmax = √(1 + 2/μ) is the classical fixed-point estimate for the undamped primary benchmark.

Design scope

A single linear mode and a preliminary harmonic TMD estimate. The entered primary damping modifies the response spectrum and damped natural frequency. A project-specific TMD requires excitation, stroke, tolerances, and damping-system analysis.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • JRC Eurocode 8 worked exampleshttps://eurocodes.jrc.ec.europa.eu/sites/default/files/2022-06/EC8_Seismic_Design_of_Buildings-Worked_examples-main_only.pdf
  • Marian and Giaralis, classical TMD comparisonhttps://openaccess.city.ac.uk/id/eprint/17700/7/Marian%20and%20Giaralis_SSS_revised%20paper_ACCEPTED.pdf

More sdof spectrum & tuned mass examples