Worked example · ASCE/SEI 7-16 §§12.8.6–12.8.7, Table 12.12-1

Soft story requiring amplification

A gravity-heavy story develops θ between 0.10 and θmax. The worksheet exposes the second-order multiplier and its effect on drift.

Calculation sheet
Export

Inputs

Drift limits
ft
in
Story actions
kip
kip

Use 1 as the ASCE default. The capacity-first convention is inverted for the code check.

Importance factor override
Importance override

Enter 0 to use the risk category.

STORY DRIFT
1.89in
DRIFT RATIO
1.313%
STABILITY θ
0.1148
DRIFT CHECK
Within limit
Amplified drift and force required

Evaluate P-Delta effects explicitly or apply 1/(1 − θ) to first-order story forces and drifts.

Drift: Within limit

The comparison includes the amplified drift when the simplified P-Delta multiplier applies.

Deflected story frameElastic / design displacementδₓₑ 0.63 inΔ 1.89 inStability thresholdsStability coefficientθ = 0.114800.25Amplification threshold0.10Stability limit θmax0.1852P-Delta multiplier1.1297
Elastic and amplified deformations are exaggerated for comparison. The gauge identifies both code thresholds.

Calculation detail

Risk or override Iₑ
1
Elastic drift δₓₑ
0.63 in
Allowable ratio
2%
Allowable displacement
2.88 in
Code ratio β (demand/capacity)
0.9
Maximum stability θmax
0.1852
Stability check
Amplify
P-Delta multiplier
1.1297
Drift after P-Delta
2.135 in

How the calculation works

Read this example

Compare first-order drift with the amplified value and use consistent story forces for explicit second-order analysis.

Preset result: STORY DRIFT 1.89 in.

Convert the analysis drift

Design story drift Δ = Cᴅδₓₑ/Iₑ. Divide by the story height in consistent units and compare against the specified screening row of Table 12.12-1. Most masonry shear walls use 0.007, and masonry cantilever shear walls use 0.010.

Evaluate stability before applying amplification

θ = PₓΔIₑ/(VₓhₛₓCᴅ) and θmax = min(0.5/(βCᴅ), 0.25). Above θmax, the story is potentially unstable. Within the maximum, θ greater than 0.10 requires explicit second-order analysis or the permitted 1/(1 − θ) amplification.

Check the qualifications for drift exceptions

The ≤4-story row assumes the relevant interior and exterior assemblies accommodate drift. The single-story exception also requires detailed drift accommodation. Building separation and the special requirement for certain moment frames in seismic categories D–F are separate checks.

Design scope

Use drifts and forces from the applicable seismic analysis in the same direction. Check building separation, moment-frame rules, and drift compatibility in addition to this worksheet.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • FEMA P-749 seismic design conceptshttps://www.fema.gov/sites/default/files/documents/fema_p-749-earthquake-resistant-design-concepts_112022.pdf
  • FEMA P-1051 design exampleshttps://www.fema.gov/sites/default/files/2020-07/fema_nehrp-seismic-provisions-examples_p-1051_20160701.pdf

More story drift & p-delta examples