Worked example · ASCE/SEI 7-16 §12.8.4, Table 12.3-1
Clustered walls with extreme edge drift
Wall lines cluster near the center and leave one side flexible in rotation. The center of mass is shifted to the far edge.
Calculation sheet
Export
Inputs
RIGIDITY X
60ft
RIGIDITY Y
33.465ft
EDGE RATIO
1.9605
MAX WALL
191.558kip
Extreme torsion screen
Compare the independent X and Y edge ratios. The signed combined cases preserve force equilibrium. The no-relief column adds peak torsional magnitude to direct magnitude.
The plan places both centers and all active wall lines. The bars compare signed-case envelopes with no-relief demand.
Calculation detail
Total X stiffness
142 kip/ft
Total Y stiffness
86 kip/ft
Rotational stiffness J
92,981.324 kip·ft/rad
CM − CR in X
30 ft
CM − CR in Y
24.535 ft
Accidental offset X (±)
6 ft
Accidental offset Y (±)
4 ft
Inherent torque
-1,560.423 kip·ft
Peak |torque|
3,252.423 kip·ft
Wall shear — signed cases and magnitudes
Wall
Direct (kip)
+X/+Y (kip)
+X/−Y (kip)
−X/+Y (kip)
−X/−Y (kip)
Envelope (kip)
No relief (kip)
X · 1
Direct (kip)158.4507
+X/+Y (kip)141.4674
+X/−Y (kip)159.7901
−X/+Y (kip)125.3435
−X/−Y (kip)143.6662
Envelope (kip)159.7901
No relief (kip)191.5579
X · 2
Direct (kip)66.5493
+X/+Y (kip)83.5326
+X/−Y (kip)65.2099
−X/+Y (kip)99.6565
−X/−Y (kip)81.3338
Envelope (kip)99.6565
No relief (kip)99.6565
Y · 3
Direct (kip)66
+X/+Y (kip)86.8326
+X/−Y (kip)64.3571
−X/+Y (kip)106.611
−X/−Y (kip)84.1355
Envelope (kip)106.611
No relief (kip)106.611
Y · 4
Direct (kip)66
+X/+Y (kip)45.1674
+X/−Y (kip)67.6429
−X/+Y (kip)25.389
−X/−Y (kip)47.8645
Envelope (kip)67.6429
No relief (kip)106.611
Extreme edge drifts — independent axis checks
Load case
Near edge (in)
Far edge (in)
Max / avg
X −5%
Near edge (in)-0.9411
Far edge (in)46.7632
Max / avg1.9605
X +5%
Near edge (in)-8.7151
Far edge (in)57.5735
Max / avg1.7371
Y −5%
Near edge (in)-6.1128
Far edge (in)42.95
Max / avg1.7508
Y +5%
Near edge (in)-18.3785
Far edge (in)55.2157
Max / avg1.5005
How the calculation works
Read this example
Check sensitivity before treating the diaphragm as rigid. The edge ratio uses absolute edge drifts and Aₓ = 1.
Preset result: RIGIDITY X 60 ft.
Compute the stiffness center
X rigidity is the stiffness-weighted X coordinate of Y walls. Y rigidity uses Y coordinates of X walls. J sums each wall stiffness times the square of its transverse arm to CR.
Keep signed and conservative cases visible
Combined torque is Vᵧeₓ − Vₓeᵧ. Add independent ±5% offsets in both axes. Each signed case adds the torsional force from its own rotation to the direct share. The no-relief magnitude adds the largest absolute torsional contribution to the absolute direct share.
Screen each axis for irregularity
Each active axis has two independent ±5% checks. The ratio divides the larger absolute edge displacement by the average of the two absolute values. Above 1.2 is torsionally irregular and above 1.4 is extreme.
Design scope
One-story elastic rigid-diaphragm model using orthogonal translational springs. The screen uses accidental torsion at Aₓ = 1. Check code applicability, amplification Aₓ, actual relative story drifts, load combinations, and the orthogonal load rule in the full structure.