Worked example · ASCE/SEI 7-16 §12.8.4, Table 12.3-1

Uniaxial wall demand with torsional coupling

Only X story shear is applied but the nonzero torque still activates Y-resisting walls. The Y edge-check classification is omitted because that axis has no independent story shear.

Calculation sheet
Export

Inputs

Diaphragm and center of mass
ft
ft
ft
ft
Story loading
kip
kip
Editable wall schedule

Use coordinates from the lower-left plan corner. An X wall resists X translation and a Y wall resists Y translation.

Wall 1
kip/ft
ft
ft
Wall 2
kip/ft
ft
ft
Wall 3
kip/ft
ft
ft
Wall 4
kip/ft
ft
ft
RIGIDITY X
60ft
RIGIDITY Y
40.968ft
EDGE RATIO
1.2193
MAX WALL
137.508kip
Irregular torsion screen

Compare the independent X and Y edge ratios. The signed combined cases preserve force equilibrium. The no-relief column adds peak torsional magnitude to direct magnitude.

Wall plan and eccentricityCRCMX wallY walleₓ 0 fteᵧ 17.03 ftWall shear envelopeX · 1130.09 kipX · 2137.51 kipY · 337.1 kipY · 437.1 kipSigned envelopeNo-relief magnitude
The plan places both centers and all active wall lines. The bars compare signed-case envelopes with no-relief demand.

Calculation detail

Total X stiffness
93 kip/ft
Total Y stiffness
110 kip/ft
Rotational stiffness J
358,612.903 kip·ft/rad
CM − CR in X
0 ft
CM − CR in Y
17.032 ft
Accidental offset X (±)
6 ft
Accidental offset Y (±)
4 ft
Inherent torque
-3,917.419 kip·ft
Peak |torque|
4,837.419 kip·ft
Wall shear — signed cases and magnitudes
WallDirect (kip)+X/+Y (kip)+X/−Y (kip)−X/+Y (kip)−X/−Y (kip)Envelope (kip)No relief (kip)
X · 1111.290392.492499.642592.492499.642599.6425130.0882
X · 2118.7097137.5076130.3575137.5076130.3575137.5076137.5076
Y · 3037.095422.985537.095422.985537.095437.0954
Y · 40-37.0954-22.9855-37.0954-22.985537.095437.0954
Extreme edge drifts — independent axis checks
Load caseNear edge (in)Far edge (in)Max / avg
X −5%25.568333.59241.1356
X +5%23.045935.99561.2193

How the calculation works

Read this example

Sum the signed Y reactions. Their net share cancels while the pair resists rotation.

Preset result: RIGIDITY X 60 ft.

Compute the stiffness center

X rigidity is the stiffness-weighted X coordinate of Y walls. Y rigidity uses Y coordinates of X walls. J sums each wall stiffness times the square of its transverse arm to CR.

Keep signed and conservative cases visible

Combined torque is Vᵧeₓ − Vₓeᵧ. Add independent ±5% offsets in both axes. Each signed case adds the torsional force from its own rotation to the direct share. The no-relief magnitude adds the largest absolute torsional contribution to the absolute direct share.

Screen each axis for irregularity

Each active axis has two independent ±5% checks. The ratio divides the larger absolute edge displacement by the average of the two absolute values. Above 1.2 is torsionally irregular and above 1.4 is extreme.

Design scope

One-story elastic rigid-diaphragm model using orthogonal translational springs. The screen uses accidental torsion at Aₓ = 1. Check code applicability, amplification Aₓ, actual relative story drifts, load combinations, and the orthogonal load rule in the full structure.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • FEMA P-1051 design exampleshttps://www.fema.gov/sites/default/files/2020-07/fema_nehrp-seismic-provisions-examples_p-1051_20160701.pdf

More shear-wall torsion examples