A five-nines status endpoint over one year

A small status endpoint advertises 99.999% annual availability. External probes saw 90 seconds of failure, including DNS and transport errors.

Jump to results

Inputs

Service objective
%
min
Burn-rate observations

Use the same availability indicator for each interval. Blank observations leave the corresponding alert unassessed.

% errors
% errors
% errors
% errors
% errors

Results

Runs in your browser
Remaining budget
3.756min
Allowed downtime
5.256min
Time to exhaustion
1,316,102.4min At the recent measured rate

The exhaustion estimate uses the reporting-window average.

Budget and burn rates
Budget and burn rates28.539 percent used. 3.756 min remains.Error budget used28.539%5.256 min allowed in this windowShort / long windows relative to alert threshold1 h / 5 min14.4× · No reading6 h / 30 min6× · No reading3 days / 6 h1× · No readingLong windowShort windowThreshold
Detailed results
Observed uptime100 %
Budget used28.539 %
Current burn rate0.285 ×
Reporting window burn0.285 ×
1 h burn at 14.4× threshold—
5 min burn for 1 h / 5 min—
Page for 1 h / 5 minNo reading
6 h burn at 6× threshold—
30 min burn for 6 h / 30 min—
Page for 6 h / 30 minNo reading
3 days burn at 1× threshold—
6 h burn for 3 days / 6 h—
Ticket for 3 days / 6 hNo reading

What to try

Check the probe interval against the roughly five-minute annual allowance. A probe once per minute is coarse enough to materially change the recorded impact of short outages.

How the estimate works

Error budget = (1 − SLO) × window size

A time-based budget is the outage allowance over the full reporting window. A request-based budget is the maximum whole number of eligible requests that can fail while meeting the objective.

Burn rate is the observed error rate divided by the allowed error rate. Each alert requires both windows to meet the threshold. The same 14.4×, 6×, and 1× thresholds are offered for all windows. Their budget fractions were originally set for a 30-day SLO.

Time to exhaustion projects the last five minutes of burn, or uses your full-window average when that reading is blank. For request-based objectives it assumes the reporting window’s average request volume continues.

Frequently asked questions

How much annual time does a five-nines status endpoint have for failure?

A 365-day year allows 5.256 minutes of downtime, about 5 minutes and 15 seconds.

Can I use internal load balancer health for a public status endpoint SLO?

Internal health checks measure a different path. External checks cover user-visible DNS, certificates, and routing failures as well as the endpoint.

Open SLA & error budgets calculator