Five-percent sampling for a distributed tracing fleet

Ninety-six services emit 300 spans per second each. The team is evaluating a 5% tracing sample rate at an average of 780 bytes per span.

Jump to results

Inputs

Sources and logs
lines/s
bytes
%
Metrics and traces
seconds
bytes
spans/s
bytes
%
Retention and prices
days
USD/GB
USD/GB
USD/GB
USD/GB-month

Results

Runs in your browser
30-day ingest
2.911TB
Active metric series
0
Monthly telemetry bill
$580.33/ month

The bill combines 30 days of ingest with the steady-state retained volume. Rates use decimal GB.

Monthly telemetry by signal
Monthly telemetry by signal2.911 TB after sampling. 55.315 TB avoided.Before sampling58.227 TBAfter sampling2.911 TBLogsMetricsTracesVolume saved by sampling · 55.315 TB
Detailed results
Log ingest0 GB
Metric ingest0 GB
Trace ingest2.911 TB
Metric sample rate0 samples/s
14-day retained volume1.359 TB
Ingest avoided by sampling55.315 TB
Savings from sampling$11,026.19 / month
Log ingestion cost$0.00 / month
Metric ingestion cost$0.00 / month
Trace ingestion cost$553.15 / month
Retained data cost$27.17 / month

What to try

A 5% sample leaves roughly 2.91 TB/month under a uniform-size assumption. Compare the observed post-policy span size before pricing a tail sampler that favors errors.

How the estimate works

Metric samples per second = active series ÷ scrape interval

The 30-day ingest estimate multiplies per-source signal rates by the number of sources. Logs and traces are sampled before ingestion. Metrics use active series × bytes per sample ÷ scrape interval.

Retained bytes equal the post-sampling daily ingest times the retention days, assuming steady traffic and equal billed and retained bytes. A separate retained-data rate applies to this steady-state volume.

Sampling savings compare the same workload at 100% log and trace capture. Prices use decimal GB. Adjust the byte sizes to match the meter you pay for. Cardinality-based tiers and cross-region duplication need separate charges.

Frequently asked questions

Does sampling five percent of traces always retain five percent of spans?

Random sampling can approach that share on average. Tail policies may favor long traces with more spans, so measure the kept span and byte rates.

Should sidecars and collectors be counted as tracing sources too?

Count each original span once at your billing boundary. Collectors that forward the same spans do not automatically create extra unique span volume.

Open Observability ingestion calculator