Two-week billing for edge gateway logs

Sixty-four edge gateways emit 18 logs per second of about 600 bytes each. A rule keeps 10% of bytes and the pilot stores them for 14 days.

Jump to results

Inputs

Sources and logs
lines/s
bytes
%
Metrics and traces
seconds
bytes
spans/s
bytes
%
Retention and prices
days
USD/GB
USD/GB
USD/GB
USD/GB-month

Results

Runs in your browser
30-day ingest
179.159GB
Active metric series
0
Monthly telemetry bill
$123.14/ month

The bill combines 30 days of ingest with the steady-state retained volume. Rates use decimal GB.

Monthly telemetry by signal
Monthly telemetry by signal179.159 GB after sampling. 1.612 TB avoided.Before sampling1.792 TBAfter sampling179.159 GBLogsMetricsTracesVolume saved by sampling · 1.612 TB
Detailed results
Log ingest179.159 GB
Metric ingest0 GB
Trace ingest0 GB
Metric sample rate0 samples/s
14-day retained volume83.608 GB
Ingest avoided by sampling1.612 TB
Savings from sampling$1,108.28 / month
Log ingestion cost$116.45 / month
Metric ingestion cost$0.00 / month
Trace ingestion cost$0.00 / month
Retained data cost$6.69 / month

What to try

The estimate is about $123 per month including two weeks of retained bytes. Run a short full-fidelity sample to validate the assumed bytes per line and filter ratio.

How the estimate works

Metric samples per second = active series ÷ scrape interval

The 30-day ingest estimate multiplies per-source signal rates by the number of sources. Logs and traces are sampled before ingestion. Metrics use active series × bytes per sample ÷ scrape interval.

Retained bytes equal the post-sampling daily ingest times the retention days, assuming steady traffic and equal billed and retained bytes. A separate retained-data rate applies to this steady-state volume.

Sampling savings compare the same workload at 100% log and trace capture. Prices use decimal GB. Adjust the byte sizes to match the meter you pay for. Cardinality-based tiers and cross-region duplication need separate charges.

Frequently asked questions

Does two-week edge retention reduce the price of bytes already ingested?

It changes the retained volume and its storage charge. The cost to ingest the same 30 days of filtered traffic stays fixed.

Should gateway multiline stack traces count as one line?

Use your collector’s actual record size and rate after multiline processing. The product of event count and average billable bytes is what matters.