Five annual checkpoints for a cold archive
A static archive holds 600 GB and needs five annual recovery points. It contains many identical files and has no lower-frequency recovery tier.
Jump to resultsInputs
Results
Runs in your browser- Stored archive
- 500GB
- Worst-chain restore
- 16.889h
- Modeled recovery interval
- 8,760h
The modeled restore and recovery interval meet the supplied targets. Confirm with an exercise.
| Daily tier | 0 GB |
|---|---|
| Weekly tier | 0 GB |
| Monthly tier | 0 GB |
| Yearly tier | 500 GB |
| Incrementals in worst chain | 0 |
| Retained recovery points | 5 |
| Effective reduction vs all fulls | 6 × |
| Worst restore bytes on wire | 400 GB |
| Transfer time only | 8.889 h |
What to try
Cross-check the assumed 6× aggregate deduplication and compression against the repository. A cold tier’s retrieval lead time can dominate the eight-hour preparation estimate.
How the estimate works
RTO ≈ restore preparation + bytes on wire ÷ usable restore bandwidth
The daily tier starts with one full backup followed by incrementals. Weekly, monthly, and yearly checkpoints are separate full restore points. The model assumes distinct checkpoints, steady changes, and deduplication plus compression across stored data.
The worst daily-chain restore reads a full backup and all retained incrementals. Archive dedup by itself does not reduce the logical bytes a full restore needs. The wire estimate assumes compressed transfer and uses the configured link efficiency plus preparation and replay time.
The modeled recovery point interval uses the daily-tier backup schedule when enabled, or the most frequent retained full tier otherwise. Measure actual backup delays and restore throughput to validate your recovery objectives.
Frequently asked questions
Why does a cold archive holding five 600 GB points use only 500 GB here?
The five snapshots represent 3 TB before reductions. A 4× deduplication factor and 1.5× compression factor reduce it to 500 GB in the model.
Can cold-tier recall latency be put into the yearly archive RTO?
Include expected recall and staging time in the preparation allowance. Check cold-tier retrieval limits and peak recovery conditions separately.