Five annual checkpoints for a cold archive

A static archive holds 600 GB and needs five annual recovery points. It contains many identical files and has no lower-frequency recovery tier.

Jump to results

Inputs

Protected data
GB
%
×
×
GFS retention
Recovery targets and link
Mbps
%
hours
hours
hours

Results

Runs in your browser
Stored archive
500GB
Worst-chain restore
16.889h
Modeled recovery interval
8,760h

The modeled restore and recovery interval meet the supplied targets. Confirm with an exercise.

Retention tiers and restore time
Retention tiers and restore timeStored archive 500 GB. Worst-chain restore 16.889 h. Modeled recovery interval 8,760 hStored archive500 GBDailyWeeklyMonthlyYearlyWorst restore vs target16.889 h / 24 hPreparationTransferRTO target
Detailed results
Daily tier0 GB
Weekly tier0 GB
Monthly tier0 GB
Yearly tier500 GB
Incrementals in worst chain0
Retained recovery points5
Effective reduction vs all fulls6 ×
Worst restore bytes on wire400 GB
Transfer time only8.889 h

What to try

Cross-check the assumed 6× aggregate deduplication and compression against the repository. A cold tier’s retrieval lead time can dominate the eight-hour preparation estimate.

How the estimate works

RTO ≈ restore preparation + bytes on wire ÷ usable restore bandwidth

The daily tier starts with one full backup followed by incrementals. Weekly, monthly, and yearly checkpoints are separate full restore points. The model assumes distinct checkpoints, steady changes, and deduplication plus compression across stored data.

The worst daily-chain restore reads a full backup and all retained incrementals. Archive dedup by itself does not reduce the logical bytes a full restore needs. The wire estimate assumes compressed transfer and uses the configured link efficiency plus preparation and replay time.

The modeled recovery point interval uses the daily-tier backup schedule when enabled, or the most frequent retained full tier otherwise. Measure actual backup delays and restore throughput to validate your recovery objectives.

Frequently asked questions

Why does a cold archive holding five 600 GB points use only 500 GB here?

The five snapshots represent 3 TB before reductions. A 4× deduplication factor and 1.5× compression factor reduce it to 500 GB in the model.

Can cold-tier recall latency be put into the yearly archive RTO?

Include expected recall and staging time in the preparation allowance. Check cold-tier retrieval limits and peak recovery conditions separately.

Open Backup retention & restores calculator