A 70 TB warehouse with six-hour backups

An analytics warehouse changes by 0.7% each day. The daily retention tier keeps 30 days of recovery points every six hours, in addition to weekly, monthly, and yearly fulls.

Jump to results

Inputs

Protected data
GB
%
×
×
GFS retention
Recovery targets and link
Mbps
%
hours
hours
hours

Results

Runs in your browser
Stored archive
305.763TB
Worst-chain restore
17.052h
Modeled recovery interval
6h

The modeled restore and recovery interval meet the supplied targets. Confirm with an exercise.

Retention tiers and restore time
Retention tiers and restore timeStored archive 305.763 TB. Worst-chain restore 17.052 h. Modeled recovery interval 6 hStored archive305.763 TBDailyWeeklyMonthlyYearlyWorst restore vs target17.052 h / 24 hPreparationTransferRTO target
Detailed results
Daily tier14.096 TB
Weekly tier93.333 TB
Monthly tier140 TB
Yearly tier58.333 TB
Incrementals in worst chain119
Retained recovery points145
Effective reduction vs all fulls33.196 ×
Worst restore bytes on wire42.289 TB
Transfer time only13.052 h

What to try

There are 119 incrementals between the oldest full and newest point in the single-chain model. More frequent synthetic fulls may reduce restore work and affect archive size.

How the estimate works

RTO ≈ restore preparation + bytes on wire ÷ usable restore bandwidth

The daily tier starts with one full backup followed by incrementals. Weekly, monthly, and yearly checkpoints are separate full restore points. The model assumes distinct checkpoints, steady changes, and deduplication plus compression across stored data.

The worst daily-chain restore reads a full backup and all retained incrementals. Archive dedup by itself does not reduce the logical bytes a full restore needs. The wire estimate assumes compressed transfer and uses the configured link efficiency plus preparation and replay time.

The modeled recovery point interval uses the daily-tier backup schedule when enabled, or the most frequent retained full tier otherwise. Measure actual backup delays and restore throughput to validate your recovery objectives.

Frequently asked questions

Why are there 119 incrementals for 30 warehouse days?

Six-hour spacing creates 120 retained points across 30 days. The first point is a full and the other 119 are incrementals.

Would one data warehouse backup every six hours meet a six-hour RPO?

The interval consumes the entire allowance. Add actual job completion delays and validation time before claiming the objective is met.

Open Backup retention & restores calculator