Use the W24×55 lateral properties and a 28 ft segment. Compare the plotted Lᵣ and elastic strength in metric units.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22F1 · F2
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
LTB strength curve
Limit exceeded
Yield limit Lₚ
1.443m
LTB limit Lᵣ
4.235m
Nominal Mₙ
163.244kN·m
Cᵦ factor
1.11
The point marks the entered Lᵦ. Colored bands separate yielding, inelastic LTB, and elastic LTB. The curve is capped at Mₚ.
Calculation results
Limit state
Demand
Available
Use
Major-axis bending
263.029 kN·m
146.92 kN·m
179%
Calculation values
Bracing zone
Elastic LTB
Plastic moment Mₚ
756.998 kN·m
Elastic Fcr
87.384 MPa
Available bending · LRFD
146.92 kN·m
Available bending · ASD
97.751 kN·m
SteelBeamLab / AISC 360-22 F1 · F2
W24×55 elastic LTB in SI
LRFD · Metric SI
For compact, doubly symmetric I-sections with restrained ends at the braced segment. Classify the flange and web per Table B4.1b before selecting Compact. Verify brace stiffness, load height, and the moment diagram.
Entered values
Unbraced length Lᵦ
8.534 m
Required moment Mᵣ
263.029 kN·m
Flange and web class
Both compact
Steel yield stress Fᵧ
344.738 MPa
Elastic modulus Sₓ
1.87e6 mm³
Plastic modulus Zₓ
2.20e6 mm³
Minor-axis radius rᵧ
34.036 mm
Effective radius rₜₛ
43.58 mm
Torsion constant J
491,153.082 mm⁴
Flange centroid spacing h₀
586.613 mm
Cᵦ input method
Direct Cᵦ
Entered Cᵦ
1.11
Key results
Yield limit Lₚ
1.443m
LTB limit Lᵣ
4.235m
Nominal Mₙ
163.244kN·m
Cᵦ factor
1.11
Limit-state screening
Limit state
Demand
Available
Use
Major-axis bending
263.029 kN·m
146.92 kN·m
179%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Use Cᵦ = 1.11 from the chosen input method.
Calculate Lₚ = 1.443 m and Lᵣ = 4.235 m. The entered length is in Zone 3.
Calculate nominal bending strength 163.244 kN·m and apply the selected design factor to obtain 146.92 kN·m.
Calculation basis
For compact, doubly symmetric I-sections with restrained ends at the braced segment. Classify the flange and web per Table B4.1b before selecting Compact. Verify brace stiffness, load height, and the moment diagram.
Moment gradient
F1-1 gives Cᵦ = 12.5Mmax/(2.5Mmax + 3Mᴀ + 4Mʙ + 3Mᴄ). Use absolute moments within the same braced segment. An all-zero moment diagram uses Cᵦ = 1.0.
Zone transitions
F2-5 and F2-6 set Lₚ and Lᵣ using rᵧ, rₜₛ, J, Sₓ, h₀, Fᵧ, and E. For doubly symmetric I-sections, c = 1. Supply rₜₛ from the section table or calculate rₜₛ = √(√(IᵧCw)/Sₓ).
Bending strength
F2-1 applies plastic yielding at Lᵦ ≤ Lₚ. F2-2 interpolates between Mₚ and 0.7FᵧSₓ, with Cᵦ and the cap at Mₚ. Beyond Lᵣ, F2-3 and F2-4 use the elastic LTB stress times Sₓ with the same cap.