Methodology
Design basis, assumptions, unit conventions, and references for SteelBeamLab.
Engineering use
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
SE means structural engineer and PE means professional engineer. Use project load combinations and verify geometry, material grades, bracing, service criteria, applicable codes, and every governing limit state. SteelBeamLab is an independent calculator suite.
References
- ANSI/AISC 360-22 Specification for Structural Steel Buildings and published corrections. Specification · Errata
- AISC Shapes Database v16.0 for the wide-flange and rectangular HSS presets. Shapes database
- AISC Design Guide 1, third edition, for centered compression plate bending. Design guide reference · AISC anchor and base plate FAQ
LRFD and ASD inputs
LRFD multiplies nominal resistance by φ. ASD divides nominal resistance by Ω. The suite applies the factors for the displayed limit state. Enter design loads for the selected method. Beam service inputs use unfactored service loads. H1 available strengths must come from the same design method as the entered demands.
Units and precision
The model solves in US customary units and converts the display to SI using 25.4 mm/in, 0.3048 m/ft, and 4.448221615 kN/kip. Steel E is 29,000 ksi, approximately 200,000 MPa. Bolt sizes and table values are from the inch series. Display values are rounded and report exports preserve numeric precision.
Modeled checks
- Beam bending & shear · F2 · F7 · G2 · G4
- Lateral-torsional buckling · F1 · F2
- Column buckling · E2 · E3
- Bolted connections · J3
- Column base plates · J8 · DG 1
- Beam-column interaction · H1-1 · App. 8
- Block shear & net tension · B4.3 · D2 · J4.3
- Built-up section properties · B4.1b