SteelBeamLab

Four A325 bolts in a single-shear plate

Use a centered load line of four standard 3/4 in bolts. Check the combined force and the loaded-end ligament.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22J3
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Bolt group
Inch-series F3125 bolt sizes. SI displays their converted dimensions.
Connected plate
Group forces

Bolt group and cutaway

Within modeled limits
Bolt shear
71.569kip
Bolt tension
85.067kip
Plate limit
95.977kip
Clear dist.
1.094in
Bolt group and cutawayThe plan shows the loaded end and governing clear distance. The cutaway shows the chosen shear planes through the connected plies.Plate planl_c = 1.094 inCutawaySingle sheart = 0.375 inLRFD · Bolt shear58.68%0%100% limit140%+
The plan shows the loaded end and governing clear distance. The cutaway shows the chosen shear planes through the connected plies.

Calculation results

Limit stateDemandAvailableUse
Bolt shear42 kip71.569 kip58.7%
Bolt tension with shear14 kip85.067 kip16.5%
Plate tearout42 kip95.977 kip43.8%

Calculation values

Gross shank area Aᵦ
0.442 in²
Standard hole diameter
0.813 in
Fₙᵥ used
54 ksi
Applied bolt shear stress
23.767 ksi
Unmodified Fₙₜ
90 ksi
Modified F′ₙₜ
64.184 ksi
Clear distance at end
1.094 in
Clear distance at pitch
2.188 in
Nominal bearing per bolt
43.875 kip
Nominal tearout per bolt
31.992 kip

Worked solution at the starting values

  1. Convert the group shear to stress on the bolt shear planes. The applied stress is 23.767 ksi and the adjusted nominal tensile stress is 64.184 ksi.
  2. Find the minimum clear distance 1.094 in and compare the nominal edge tearout and bearing strengths.
  3. Compare the required bolt and plate forces with available strengths. Bolt shear governs at 58.7% utilization.

Calculation basis

Use standard circular holes and equal direct force per bolt. Verify eccentricity, prying, fatigue, and each connected ply using full connection details.

Bolt rupture and interaction

Use J3.2 nominal bolt stresses with the gross shank area and the number of shear planes. J3.8 reduces Fₙₜ to F′ₙₜ as shear stress rises. The tensile capacity uses one gross shank area per bolt. For an end-loaded pattern over 38 in, reduce Fₙᵥ to 83.3%.

Bearing and tearout

J3.11a limits each bolt to min(2.4dtFᵤ, 1.2l꜀tFᵤ) when service-load hole deformation matters, and min(3.0dtFᵤ, 1.5l꜀tFᵤ) when it does not. One bolt is at the loaded end and the rest are spaced at the entered pitch. The equal-load group uses the weakest position times bolt count.

Slip-critical option

J3.9 uses μDᵤh_fTᵦnₛ per bolt. J3.10 applies the clamping reduction kₛ꜀ due to group tension. Standard holes use φ = 1.00 or Ω = 1.50 for slip. Slip-critical joints also receive the bolt rupture and plate checks.

References and units ↗

More worked examples