Worked example · Controls & protection
Twin box culverts with high tailwater
Two identical concrete boxes sit below a high downstream channel stage, with equal flow split between barrels.
Inputs
Roadway culvert profile
Live resultsHeadwater below both limits
Outlet control. Overtopping uses the actual road crest. HW/D has a separate 1.2 worksheet limit.
Calculation results
- HW / D
- 1.05
- Inlet HW
- 3.2 ft
- Outlet HW
- 4.21 ft
- Road clearance
- 1.89 ft
- Governing control
- Outlet
- Inlet condition
- Unsubmerged
- Governing headwater depth
- 4.21 ft
- Headwater elevation
- 522.21 ft
- Road crest elevation
- 524.1 ft
- Reserve to HW/D 1.2
- 0.59 ft
- Critical depth
- 1.95 ft
- Barrel friction loss
- 0.09 ft
- Entrance + exit loss
- 0.35 ft
- Full-area barrel velocity
- 3.88 ft/s
Worked calculation
Reduce the tailwater and compare outlet control with inlet control. The inlet result stays fixed as tailwater changes.
HWin from Appendix A · HWout = h₀ + hfriction + (kₑ + 1)V²/(2g) − LS · HW = max(HWin, HWout).
The inlet calculation uses HDS-5 Table A.1. A linear blend between the published branch endpoints is used near inlet submergence. The outlet is a full-barrel energy screen with h₀ = max(TW, (d꜀ + D)/2), capped at D for the starting depth proxy before taking the maximum with tailwater. For outlet headwater below 0.75D, verify with a backwater calculation. The 1.2 ratio is a worksheet criterion. Road overtopping uses the surveyed road crest.
More worked examples
Open the main calculatorTwin box culverts with high tailwater
Inputs
- Total design flow
- 186 cfs
- Inlet configuration
- Box · chamfered headwall
- Diameter or inside rise
- 4 ft
- Box inside span
- 6 ft
- Identical barrels
- 2
- Barrel length
- 96 ft
- Longitudinal grade
- 0.44 %
- Manning n
- 0.013
- Entrance loss kₑ
- 0.5
- Depth above outlet invert
- 4.2 ft
- Inlet invert elevation
- 518 ft
- Road crest above inlet invert
- 6.1 ft
Results
- HW / D
- 1.05
- Inlet HW
- 3.2 ft
- Outlet HW
- 4.21 ft
- Road clearance
- 1.89 ft
- Governing control
- Outlet
- Inlet condition
- Unsubmerged
- Governing headwater depth
- 4.21 ft
- Headwater elevation
- 522.21 ft
- Road crest elevation
- 524.1 ft
- Reserve to HW/D 1.2
- 0.59 ft
- Critical depth
- 1.95 ft
- Barrel friction loss
- 0.09 ft
- Entrance + exit loss
- 0.35 ft
- Full-area barrel velocity
- 3.88 ft/s
Headwater below both limits
Outlet control. Overtopping uses the actual road crest. HW/D has a separate 1.2 worksheet limit.
HWin from Appendix A · HWout = h₀ + hfriction + (kₑ + 1)V²/(2g) − LS · HW = max(HWin, HWout).
Screening worksheet · Verify design using project criteria and site data.