Spindle diameter gage study
AIAG MSA · 4th edition / SI units
- GRR sigma
- 1.243424 µm
- GRR study var
- 12.109 %
- GRR tolerance
- 14.921 %
- Distinct groups
- 11
Inputs
- Input mode
- Raw crossed study
- Verdict basis
- % study variation
- Appraisers
- 3
- Trials per part
- 2
- Parts
- 10
- LSL
- 14.975 mm
- USL
- 15.025 mm
Raw readings (mm), grouped by appraiser
- Part 1
- 14.9822 / 14.982867 · 14.984133 / 14.982467 · 14.983733 / 14.9844
- Part 2
- 14.9858 / 14.9868 · 14.987733 / 14.9864 · 14.987333 / 14.988333
- Part 3
- 14.9894 / 14.990733 · 14.991333 / 14.990333 · 14.990933 / 14.992267
- Part 4
- 14.993 / 14.993667 · 14.994933 / 14.993267 · 14.994533 / 14.9952
- Part 5
- 14.9966 / 14.9976 · 14.998533 / 14.9972 · 14.998133 / 14.999133
- Part 6
- 15.0002 / 15.001533 · 15.002133 / 15.001133 · 15.001733 / 15.003067
- Part 7
- 15.0038 / 15.004467 · 15.005733 / 15.004067 · 15.005333 / 15.006
- Part 8
- 15.0074 / 15.0084 · 15.009333 / 15.008 · 15.008933 / 15.009933
- Part 9
- 15.011 / 15.012333 · 15.012933 / 15.011933 · 15.012533 / 15.013867
- Part 10
- 15.0146 / 15.015267 · 15.016533 / 15.014867 · 15.016133 / 15.0168
Measurement system components
| Component | Sigma | Study var. | Contribution | Tolerance |
|---|---|---|---|---|
| EV | 0.97482 µm | 9.4932 % | 0.90121 % | 11.698 % |
| AV | 0.7718998 µm | 7.5171 % | 0.56507 % | 9.2628 % |
| GRR | 1.243424 µm | 12.109 % | 1.4663 % | 14.921 % |
| PV | 10.19304 µm | 99.264 % | 98.534 % | 122.32 % |
| TV | 10.2686 µm | 100 % | 100 % | 123.22 % |
Range checks
| Check | Result |
|---|---|
| R̄̄ · average repeat range | 1.1 µm |
| X̄diff · appraiser mean range | 1.533333 µm |
| Rp · part mean range | 32.4 µm |
| K₁ / K₂ / K₃ | 0.8862 / 0.5231 / 0.3146 |
| ndc ≥ 5 | Met |
| R upper control limit | 3.5937 µm |
| X̄ control interval | 14.99758 mm to 15.00172 mm |
| R above UCL | 0 / 30 |
| X̄ outside control limits | 26 / 30 |
Verdict based on % study variation. ndc meets the screening goal. Use representative parts and blinded, randomized repeats. The method does not estimate appraiser × part interaction. A zero observed GRR gives no finite reliability estimate for ndc.