Mold insert micrometer study
AIAG MSA · 4th edition / SI units
- GRR sigma
- 2.430238 µm
- GRR study var
- 31.348 %
- GRR tolerance
- 36.454 %
- Distinct groups
- 4
Inputs
- Input mode
- Raw crossed study
- Verdict basis
- % study variation
- Appraisers
- 2
- Trials per part
- 2
- Parts
- 10
- LSL
- 7.48 mm
- USL
- 7.52 mm
Raw readings (mm), grouped by appraiser
- Part 1
- 7.4846 / 7.4858667 · 7.4889333 / 7.4857667
- Part 2
- 7.4872 / 7.4891 · 7.4915333 / 7.489
- Part 3
- 7.4898 / 7.4923333 · 7.4941333 / 7.4922333
- Part 4
- 7.4924 / 7.4936667 · 7.4967333 / 7.4935667
- Part 5
- 7.495 / 7.4969 · 7.4993333 / 7.4968
- Part 6
- 7.4976 / 7.5001333 · 7.5019333 / 7.5000333
- Part 7
- 7.5002 / 7.5014667 · 7.5045333 / 7.5013667
- Part 8
- 7.5028 / 7.5047 · 7.5071333 / 7.5046
- Part 9
- 7.5054 / 7.5079333 · 7.5097333 / 7.5078333
- Part 10
- 7.508 / 7.5092667 · 7.5123333 / 7.5091667
Measurement system components
| Component | Sigma | Study var. | Contribution | Tolerance |
|---|---|---|---|---|
| EV | 1.96441 µm | 25.339 % | 6.4208 % | 29.466 % |
| AV | 1.430787 µm | 18.456 % | 3.4063 % | 21.462 % |
| GRR | 2.430238 µm | 31.348 % | 9.8271 % | 36.454 % |
| PV | 7.36164 µm | 94.959 % | 90.173 % | 110.42 % |
| TV | 7.752406 µm | 100 % | 100 % | 116.29 % |
Range checks
| Check | Result |
|---|---|
| R̄̄ · average repeat range | 2.216667 µm |
| X̄diff · appraiser mean range | 2.116667 µm |
| Rp · part mean range | 23.4 µm |
| K₁ / K₂ / K₃ | 0.8862 / 0.7071 / 0.3146 |
| ndc ≥ 5 | Below goal |
| R upper control limit | 7.24185 µm |
| X̄ control interval | 7.494109 mm to 7.502444 mm |
| R above UCL | 0 / 20 |
| X̄ outside control limits | 14 / 20 |
Verdict based on % study variation. Discrimination needs review. Use representative parts and blinded, randomized repeats. The method does not estimate appraiser × part interaction. A zero observed GRR gives no finite reliability estimate for ndc.