Chamber pump-down time / Worked example
Roots-Boosted Coating Vessel
A 3.2 m³ coating vessel uses 65 L/s backing-only speed with a 240 L/s combined speed below 800 Pa.
Inputs
Roots booster
Walls, seals and leaks
Live readout
Target vacuum met- Roughing time
- 299.8 s
- Backing-only roughing time
- 238.3 s
- Boosted roughing time
- 61.4 s
- High-vacuum stage
- 321.2 s
- Time to target
- 621 s
- Modeled ultimate pressure
- 6.765e-8 Pa
- Wall throughput at target
- 2.701e-4 Pa·m³/s
Reading this example
The change in log-pressure slope shows where the booster saves time. Use the vendor cut-in pressure as the operating constraint.
Model & assumptions
Roughing stages
t = (V/S) ln(Pₐ/Pᵦ)
The backing pump runs above the Roots switch pressure. Use combined speed below the switch, until the high-vacuum pump takes over. Enter chamber-effective speeds for all stages.
High-vacuum mass balance
V dP/dt = A[q∞ + q₁(1 + t/t₁)⁻ᵅ] + Qₗ − SₑP
The high-vacuum clock starts with wall age t₁. The solver integrates the decaying load with exponential chamber memory until pressure crosses the target. At α = 0 the reference wall rate is a steady load.
Ultimate pressure
P∞ = (Aq∞ + Qₗ)/Sₑ (α > 0)
The model rejects a target at or below the ultimate pressure. With a decaying wall load, a target can sit above the floor and still take longer than the 10¹² s search horizon.