Chamber pump-down time / Worked example

Wafer Load Lock Cycle Time

A 36 L load lock starts each cycle at atmosphere. A dry scroll pump hands off to high vacuum at 12 Pa without a Roots booster.

Readout ↓

Inputs

Chamber and effective speeds
L
Pa
Pa
Pa
L/s
L/s
Roots booster
Walls, seals and leaks
m²
Pa·m³/(s·m²)
s
Age at the start of the high-vacuum stage.
Pa·m³/(s·m²)
Pa·m³/s

Live readout

Target vacuum met
Roughing time54.25sHigh-vac time4.184sTotal time58.43sUltimate floor2.843e-7PaS₁Backing54.2 sS₂Roots bypass0 sS₃High vacuum4.18 sLog P · Pa vs log-spaced time (s)2.84e-70.171.01e505.2768.4Roots cut-inInactiveTarget P2e-3 PaFloor P2.84e-7 Pa
Roughing time
54.25 s
Backing-only roughing time
54.25 s
Boosted roughing time
0 s
High-vacuum stage
4.184 s
Time to target
58.43 s
Modeled ultimate pressure
2.843e-7 Pa
Wall throughput at target
2.349e-6 Pa·m³/s

    Reading this example

    The roughing time sets the first part of the cycle. The wall load and final decade can dominate the high-vacuum finish.

    Model & assumptions

    Roughing stages

    t = (V/S) ln(Pₐ/Pᵦ)

    The backing pump runs above the Roots switch pressure. Use combined speed below the switch, until the high-vacuum pump takes over. Enter chamber-effective speeds for all stages.

    High-vacuum mass balance

    V dP/dt = A[q∞ + q₁(1 + t/t₁)⁻ᵅ] + Qₗ − SₑP

    The high-vacuum clock starts with wall age t₁. The solver integrates the decaying load with exponential chamber memory until pressure crosses the target. At α = 0 the reference wall rate is a steady load.

    Ultimate pressure

    P∞ = (Aq∞ + Qₗ)/Sₑ (α > 0)

    The model rejects a target at or below the ultimate pressure. With a decaying wall load, a target can sit above the floor and still take longer than the 10¹² s search horizon.